ods & Vented Range Ho Noncompliance Safety Information... 2.3 Operating/Care and Cleaning Instructions Charcoal Filters 5 Grease Filters Hood Lights... Painted Surfaces Stainless Steel Surfaces .. vent Controls... installation Instructions.
IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. SAFETY PRECAUTIONS A WARNING = TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended Dy the manufacturer, if you have questions, contact the manufacturer B.
Using the hood controls. Throughout this manual features and appearance may vary from your model Rocker Switch Controls ) ’ GFF Hi 4 OFF Ee FAN LIGHT FAN Control @ LIGHT Control Press the rocker switch at the top to turn the fan on Ht and at the bot torn to turn it on LOW. The center position is OFF. the fight OFF. Continuous use of the fan system while cooking helps keep the kitchen comfortable and less humid. it lase reduces cooking odors and dolling ravisher that create o frequent need for cleaning.
Care and cleaning of the vent hood. Misapplication The charcoal filters. + cannot be cleared. Order Kit ro. WEO2X11000. | This kit car be ordered The charcoal fitters are clipped rom your GE supplier inside of each reusable metal They must be replaced. Charcoal Filters fon sore models NOTE: Chocoholic filters are not included with the hood. They must be ordered from your | GF supplier.
Installation instructions Range Hood Questions? Coll 800.GE.CARES (800.432.2737) or Visit our Website at: Noncompliance BEFORE YOU BEGIN Read these instructions completely and carefully. * IM PORTENT = Save these instructions for local inspector's use. IM PORTENT = Observe all governing codes and ordinances, Note to Installer Be sure to leave these instructions with the Consumer.
Installation Instructions WORKSHEET CALCULATE TOTAL EQUIVALENT DUCT WORK LENGTH putty EQUIVALENT NUMBER puce EQUIVALENT NUMBER PIECES LENGTH x USED = TOTAL PIECES LENGTH x USED TOTAL IWR 107 JIE Round, Sect, 0p 90° elbow straight i EA round fort Round, elbow ] straight yr TA 7" Round | 28 Ft Clio) 347% 107 114 see twill cop [21 fo wio (Er Sect. 90° with doper) ER Fr elbow parader a | 37107 [BFC Round Sect. 457 rout cap elbow = 7" Round |1 Ft wtb = Ft 3H 107 Sect. 90° 3107 flit elbow cert.
Installation Instructions TOOLS YOU WILL NEED = |f the unit is darn aged in shipment, return the unit to the store in which it was bought for repair or replacement. EE Brats the unit is damaged by the customer, repair of Sn replacement is the responsibility of the cornerstone. Flat blade ond? Flips ip Pencil Out tape = If the unit is garaged by the installer {if other than the customer), repair of replacement must be made by arrangement between customer and installer.
Installation Instructions [Il CHOOSE VENT OPTION Determine the vent option that your installation will require Fromm the fallowing chalices: The outside vent exhaust option that your installation requires will determine the hood knockouts that you will use. IMPORTANT: If the hood is to be installed in o recirculating, non-vented ductless manner, do not knock out any vent openings in the hood. Only an electrical access hale will be knocked out of the hood.
Installation Instructions [2] REMOVE FILTERS Remove the protective shipping film from the edges of the metal grease filters. Press the filter locks back and lift the filters aut. Set them aside [3]REMOVE WIRING COVER FROM THE JUNCTION BOX Waverer the wiring cover from inside the hood Set the cover and its mounting screw aside.
Installation Instructions [6] FOR 3%" x 10” RECTANGLE DUSTED DISCHARGE INSTALLATIONS: Attach exhaust adoptor/damper over knockout opening with two exhaust adapter screws. Make sure darner pivot is nearest to bucktooth edge of hood. Remove tape from damper flap. Up to 17 side-to J : Tape side adjustment Buckteeth edge Exhaust adaptability vertices discharge position shown NOTE: The exhaust adaptability con be installed up to 1 inch on either side of the hood center to accommodate off-center outward.
Installation Instructions CHOOSE VENTING OPTION The hood con be set to vent outside or to recirculate air back inch the kitchen a To vent to the outside, refer to steps Sand 6 * Yo recirculate air into the kitchen, remove two screws securing the duct block off plate. Discard plate. Replace two screws. Note: Hood is €: v STar® certified ably when it vents air to the outside.
Installation Instructions CONNECT DUCT WORK TO HOOD Use duct tape to make joints secure ond air tight. Note: illustration shows rectangular to round duct adapter. &r nod Duct wpe INSTALL LAMPS A WARNING: 9) Lamp contains Mercury, Manage in accord with disposal laws, See wiwwlamprecycleorg or 1-B00-435-4448. Far installation, handling and disposal precautions, refer to the fluorescent lamp packaging literature.
Before you call for service... Troubleshooting Tips Save time and money! Review the following chart first and you ray not need to call for service. Feb Possible Causes What To Do Fan does not operate when the switch is on A fuse may be blown or a circuit breaker may be tripped. + Replace fuse or reset circuit breaker. Fon foils to circulate air or.moves air more slowly than normal Excessively soiled filter. « Wash and replace the filters.
GE Range Hood Warranty. 7 All warranty service provided by our Factory Service Centers, Staple your receipt here, 7 fag or an authorized Customer Care® technician. To schedule service Proof of the original purchase Tr online, visit us of Noncompliance, or call 800.GE.CARES date is needed to plantain service (800.432 2737). Please have serial number and made! number under the warranty, available when calling for service.
Consumer Support. GE Appliances Website Noncompliance Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner's Manuals, order parts or even schedule service on-line. Schedule Service Noncompliance Expert GE repair service is only one step away from your road. Get on-line and schedule your service at your convenience any doy of the year! Or call BOLIVARES (800.432.
GEAppliances.com Campanas de estufas . F con ventilación Información de seguridad... 2 Instrucciones de operación / Cuidado y limpieza Controles de 3 Filtros de carbón. oo 4 Filtros para la grasa. . 3 Luces de la campana ou 4 Superficies de acero inoxidable Lo 4 Superficies de la campana 4 Instrucciones de instalación. L512 Solucionar problemas 13 Soporte al consumidor Soporte al consumidor Y. 16 Tragontina. Y.
Uso de los controles de la campana. GEAppliances.com Alo Sorgo de este manual, los funciones y el aspecto pueden ser diferentes a los de su modelo. Controles interruptores de presión fen algunos modelos} OFF LIGHT 1 oN € control dol VENTILADOR Presione ef interruptor en la parte superior pare encender of verticilo en lo velocidad ata [Chillo en la parte inferior para reducirlo a belio LOE.
Cuidado y limpieza de la campana de ventilación. Los filtros de carbón están unidos al interior de cada filtro metílico pero fo grasa. Filtros de carbón fea algunos modelos) Los filtros de carbón no se pueden limpiar, sino gue se deben reemplazar, Ordene el kit vo, WEOZRI0707:, Estos bits se pueden ordenar o.través de su proveedor GE. NOTA: Los filtros de carbón no están incluidos con la camparía. Deben ser arenados de su suplidor GE.
Instrucciones de instalación Campana para estufa Preguntas? Líame al 800.GE.CARES [800.432.2737] o Visite nuestro sitio Web: GEAppliances.com ANTES DE EMPEZAR Lea estas instrucciones completa y cuidadosamente. * IMPORTANTE ~~ Guarde estas IMPORTAR uso del inspector local IMPAR ANTE ~ Observe todos {os códigos y ordenanzas vigentes. Nota para el instalador Resarcir de dejo estas instructores en poder del consumidor. Nota para el consumidor = Mantenga estas instrucciones pare referencia futuro.
Instrucciones de instalación [2] RETIRE LOS FILTROS Retire a película protectorio de empegue de los bordes de los filtros metédmelos para la grasa. Presione los bloqueos del filtro y levan los filtros hacia fuera, Colguemos a un lado.
Instrucciones de instalación [6] PARA INSTALACIONES DE SALIDA RECTANGULAR CON DICTO UNICAMENTE: Una el adaptador del estrangulador de tiro sobre lo abertura ciega con los dos tomillos adaptadores del escape. Cerciórese de que el gfe esté mds cerca al borde superior/posterior de lo campana. Retire lo cinta de la tapa del regulador de vito.
Instrucciones de instalación [8] ESCOGER LA OPCIÓN DE VENTILACIÓN Lat campana puede justarse par ventilar hacia el exterior o para re circular el aire de regrese hacia lo cocina * Para ventilar hacia ef exterior, consulte los pasos Sy 6. * Para re circular el aire hacia la cocina, quite los dos tomillos que fijan el bloque del conducto de la placa. Elimine lo placa. Vuelva a colocar los dos tornillos Nota: La campana se encuentra certificada por Envenene Sma® solo cuando elimina aire al exterior.
Antes de llamar a solicitar servicio... Consejos para ka solución de problemas ahorre tiempo y dinero Revise lu siguiente tabla primero quizás no necesite llamar a solicitar servicio. GEAppliances.com Poblemos || Posibles Causas Qué hacer El ventilador no opera cuando el interruptor, se enciende Quizás se haya quemado un fusible ¢ se hoya saltado ef interruptor de circuitos. « Reemplace el fusible o licenciare el interruptor de circuitos.
Garantía de GE para su campana para ventilación de estufa. Todos los servicios de tragontina fos proporcionan nuestros Centros de Reparación de Fabrica o nuestros técnicos Custodie Care® autorizados. Para concertar una cita de reparación en linea, visítenos en GEApplionces.com, o lame af 800.GE.CARES (800.432.2737). Cuando filare por solicito servicio, por favor tenga a mano el animero de serie y el merendero de modelo. Pegue aquí su recibo.