Installation Guide

31-11120-1 3
Installation Instructions
CONNECTION METHOD FOR JVX5305 AND JVX5365
PARTS NEEDED
■ 2-Position wall switch - Qty (2).
■ Electrical wire to connect to wall switch in accordance
with local codes.
■ Wire nuts. Use appropriate wire nuts for size of the
electrical wire.
■ 18 gage black wire.
0
RED
1b 1a
BLK
WHT
M8/35 2V
1
VLT
1
BLK
1
RED
BLK
BLK
TE N
LINE
120Vac 60Hz
2
F
LAMP
VLT
0
(WHT-GRY)
1
WIRING BOX
1
OFF
EXTERNAL
CONTROL
ON-OFF
MOTOR
2
OFF
BLK
VLT
BLK
BLK
BLK
BLK
RED
LAMP
VLT
LAMP
LAMP
1b
G
LINE
120Vac
60Hz
RED
WHT
BLK
RED
WHT
BLK
RED
WHT
BLK
W
HT
BLK
WHT
BLK
BLK
WHT
WHT
ON-OFF
LIGHTING
(WHT-GRY)
(BLU)
WIRING BOX
(BLU)
M8/35 2V
HOOD INTERNAL CONTROL
HOOD EXTERNAL CONTROL
1b 1 1a 1b 1 1a 1b 1 1a
This connection method allows switching fan and lights on or off on the range hood using wall switch only. The
rocker switch on the range hood will function and must be kept in on position to allow control of range hood using
wall switch. For fan, the wall switch will turn the fan to speed pre-selected on range hood rocker.
Step 1: To establish connection of hood fan to wall
switch, locate the hood junction box and remove its cover.
Step 2: Remove the access panel in the hood to access
the wiring attached to the range hood rockers.
Step 3: Connect the black wire in the junction box
coming from the fan range hood rocker to 2 position wall
switch.
Step 4: Run power to the 2 position wall switch to
control the fan using wall switch.
Step 5: To establish connection of hood lights to wall
switch, cut the black wire coming from the light range
hood rocker to the middle connector on fan range hood
rocker and cap the end attached to the fan range hood
rocker using appropriate size wire nut.
Step 6: Connect a black 24” min. length 18 gage wire to
the black wire that was cut coming from the light range
hood rocker using appropriate size wire nut. Run the
black wire through the conduit into the junction box to
make sure the wire is not exposed to any sharp edges.
Step 7: Connect the black wire added into the junction
box to 2 position wall switch.
Step 8: Run power to the 2 position wall switch to
control the lights using wall switch.
Step 9: Re-install the access panel and junction box
cover using the screws.
Wiring Diagram 991.0438.625