Specification

PGP9830SR
GE Profile
Series 30" Downdraft Gas Cooktop
For answers to your Monogram, GE Café
Series, GE Profile
Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center
®
Service, 800.626.2000.
Specification Revised 8/22
INSTALLING THE DUCTWORK: Use
galvanized or aluminum duct in 6" round
or 3-1/4" x 10" size, or combination of
both. PVC duct or locally approved
piping should be used if installing under
a poured concrete slab. Local building
code must be followed in specifying
type and schedule of all duct used.
NOTE: Ductwork must be vented to
outside. Do not vent into a wall, ceiling,
crawlspace, attic or any concealed
space. Always use an appropriate roof
or wall cap with damper. Laundry-
type wall caps should never be
used. For maximum efficiency use
the shortest and straightest duct
run possible,
with as few fittings as
possible. For satisfactory
performance
the duct run should not exceed 100
feet equivalent length. Refer to the
table of equivalent lengths (shown in
installation instructions) for various duct
configurations.
REAR WALL VENTINGDOWNWARD VENTING