Specification
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
PHP7036DT 
GE Profile
™
 36" Built-In Touch-Control Induction Cooktop 
For answers to your Monogram, GE Café
™
, GE Profile
™
 or GE Appliances 
product questions, visit our website at geappliances.com or call  
GE Answer Center
®
 Service, 800.626.2000.
ADA
COMPLIANT
Listed by 
Underwriters 
Laboratories
Specification Revised 10/22
36"
1-3/4" MIN.
to rear wall
18-7/8"
33-3/4"
19-1/8" to
19-1/4"
33-7/8"
to 34"
2-1/2" MIN.
Required
Cooktop
To insure accuracy, it is best to make a
template when cutting the opening in the counter
20-1/2"
13" MAX. depth of unprotected
overhead cabinets
2" MIN. Clearance
from cutout to nearest
vertical wall or cabinet
on right side of the unit
below the 15" MIN.
clearance height.
15" MIN. height
from countertop
to nearest cabinet
(including light rails)
on both sides of
cooktop
30" MIN. Clearance from
countertop to unprotected
overhead surface
See label next
to nameplate for
MIN. clearance
to rear wall.
2" MIN. clearance
to side wall from cut-out
on the left of the unit
4-5/8" at baffle near center 
of unit (except when installed
above an approved wall 
oven) and 3-1/4" at rear 
of air intake
IMPORTANT: Requires a 3" free area between 
the bottom of the cooktop to any combustible 
material, i.e., shelving. Free area not required 
when installing wall oven underneath cooktop. 
Refer to installation instructions. Requires a 15" 
minimum from cooktop to adjacent overhead 
cabinets. Units are furnished with a 48" flexible 
armored cable. 
NOTE: 36" induction cooktops are approved 
for use over select GE 30" Single Wall Ovens 
and Warming Drawers. Refer to cooktop 
and wall oven/warming drawer installation 
instructions packed with product for current 
dimensional data. If installed with a GE 
Telescopic Downdraft System, consult both 
the cooktop and downdraft installation 
instructions packed with product before 
installing. Cooktop gas/electric supply may 
need to be re-routed to install downdraft. The 
countertop cutout requires 23-1/2" minimum 
flat countertop surface and 25" minimum total 
countertop depth. In addition, other clearances 
to front edge of the countertop must be 
considered.  
Before installing, consult installation 
instructions packed with product for  
current dimensional data. 
APPROXIMATE COOKING DIMENSIONS
KW R ATING
240V 11.6
208V 10.1
AMPERAGE
240V 50 Amps
†
208V 50 Amps
†
†
NOTE: Check local 
codes for required 
breaker size.
2-1/2" MIN
From front edge
of countertop to front
edge of cooktop cutout
31-1/4" MIN
From top surface
of countertop to
top surface of
wall oven support
platform
INSTALLATION ABOVE A WALL OVEN