PARTS THAT KEEP YOU COOL Room Air Conditioner Accessories
VERTICAL ZONELINE UNITS ® 2
VERTICAL ZONELINE UNITS ® RAVWP6 (AZ Series*—75/85) Wall Plenum • Wall plenum for installation in walls less than 6" thick • Wall plenum 19-3/4" x 32" • Wall cutout dimensions 20" x 32-1/4" • Warm gray beige color RAVWP8 (AZ Series*—75/85) Wall Plenum • Wall plenum for installation in walls less than 8" thick • Wall plenum 19-3/4" x 32" • Wall cutout dimensions 20" x 32-1/4" • Warm gray beige color RAVWP12 (AZ Series*—75/85) Wall Plenum • Wall plenum for installation in walls less than 12" thick • Wall p
VERTICAL ZONELINE UNITS ® RAVAL1 (AZ Series*—75/85) Aluminum Outdoor Grille • Extruded aluminum outdoor grille for installation on RAVWP series wall plenums • Grille is 19-3/4" x 32" x 1-1/4" • Mill finish RAVRG1 (AZ Series*—75/85) Access Panel with Return Air Grille • Access panel with return air grille for installation in closet wall • Allows access/removal of Vertical Zoneline for cleaning or service • Outside dimensions 30" x 50" • Wall cutout dimensions 28" x 48" • Accepts 20" x 20" x 1" field-suppli
VERTICAL ZONELINE UNITS ® RAK5157/5207/5307† (AZ Series*—75/85) 265/277-Volt Universal Power Supply Kit • 9-pin connector with three 7" 12-gauge conductor wires. Circuit Kit No. Volts Heater Wattage Ampacity RAK5157 265/277 2.71 kw 15 RAK5207 265/277 3.55 kw 20 RAK5307 265/277 5.03 kw 30 RAK4157/4207/4307† (AZ Series*—75/85) 230/208-Volt Universal Power Supply Kit • 9-pin connector with three 7" 12-gauge conductor wires. Circuit Kit No.
ZONELINE UNITS ® 6
ZONELINE UNITS ® RAB71A (All Zoneline Series) Standard Wall Case The RAB71A is a galvanized steel wall sleeve with expanded polystyrene foam insulation. It is mechanically fastened and protected with bakedon enamel and protected with a sealing compound to prevent rust. The RAB71A wall case accepts all Zoneline chassis models.
ZONELINE UNITS ® RAF453A (AZ Series*—28, 29, 38, 39, 41, 58 and 61 only) Replacement Standard Room Cabinet Room cabinet with wraparound design has attractive textured finish which matches unit sleeve. Cabinet is injection-molded of high-impact polystyrene. Cabinet fastens to chassis without tools or hardware. The room cabinet contains the slide-out filters and 2-position reversible discharge louvers.
ZONELINE UNITS ® RAKOIM (AZ Series*—22, 32 and 52 only) Optional Interface Module for Central Desk Control or Remote Thermostat Control The RAKOIM is required if a unit is to be installed with a Central Desk Control or a Remote Thermostat Control. Includes screw, and a short wire harness on the RAKOIM that is plugged into the mating receptacle on the front of the control box.
ZONELINE UNITS ® 8-3/8" 6-1/2" RAK7012 (AZ Series*—22, 25, 32, 35, 28, 29, 38, 39, 41 and 61) Duct Adapter for Replacement of A_B with Rounded-Front AZ Chassis The RAK7012 duct adapter is designed to line up with the duct extension where the original chassis was a flat-top discharge A-B Series. Using the RAK7012 will allow the existing duct extension to be used without requiring the relocation of the hole through the wall to the adjacent room.
ZONELINE UNITS ® Chaseway Power cord and junction box not included with sub-base. RAK204 (AZ Series*) Standard Sub-Bases WITHOUT power cord included The RAK204 sub-base is made of heavy-gauge steel to provide support of the wall case. It has full base enclosure with breakaway side channels, simple connection to wall case and 4-point leveling legs. The sub-base will adapt to service conduit, circuit breakers and receptacles up to 30 amps.
ZONELINE UNITS ® RAK4157/4207/4307† (AZ Series*—28, 29, 38, 39, 41, 55, 58 and 61 only) 230/208-Volt Universal Power Supply Kit • 9-pin connector with three 7" 12-gauge conductor wires. Circuit Kit No. Volts Heater Wattage Ampacity RAK4157 230/208 2.4/2.32 kw 15 RAK4207 230/208 3.3/3.2 kw 20 RAK4307 230/208 4.7/4.53 kw 30 RAK5157/5207/5307† (AZ Series*—28, 29, 38, 39, 41, 55, 58, 61) 265/277-Volt Universal Power Supply Kit • 9-pin connector with three 7" 12-gauge conductor wires Circuit Kit No.
ZONELINE UNITS ® RAK4002 (while quantities last) (AZ Series*—22, 32 and 52 only) Direct-Connect Junction Box (230/208 and 265/277 Volts) RAK4002 junction box kit for permanent connection of 230/208- and 265/277-volt units to building power supply. Includes multi-circuit connector harness for use on value line units. Junction box is included on 265/277-volt units.
ZONELINE UNITS ® RAK806 Universal Cover Label (10 covers per kit) The RAK806 provides a cover for the control area to refer room occupant to use a remote thermostat. Double-sided tape provided. RAA62 (AZ Series*—22, 32 and 52 only) Replacement Filters for AZ Models (20 pairs per box) The up-front filters on the GE Zoneline unit are conveniently accessed by simply pulling them up from the top of the room cabinet.
BUILT-IN UNITS 15
BUILT-IN UNITS RAD4A1 Drain Kit Internal/External Drain Kit Drain kit for use on “J” series wall cases. For more positive control of condensate water, the RAD4A1 drain kit routes condensate to the exterior or to the interior of the building through the wall case. Suitable provision (field applied) should be made to connect the drain tube to a drain system in the building. Drain tube assembly is 1/2" O.D. copper. Note: The RAG14E exterior grille is NOT compatible with the RAD4A1 EXTERNAL drain tube.
BUILT-IN UNITS RAG13A Stamped Aluminum Exterior Grille “J” Series Used to replace exterior grille on old “J” wall case to maximize efficiency and capacity of new chassis. The grille is included with new wall cases RAB46A, 47A, 48A and 48B. RAG14E Architectural Louvered Exterior Grille for “J” Series Extruded aluminum grille for application with RAB46A, 47A, 48A and 48B. NOTE: The RAG14E exterior grille is NOT compatible with the RAD4A1 EXTERNAL drain tube.
BUILT-IN UNITS RAA72 Replacement Filter for Rounded-Front “J” Chassis (1997–2000) • Replacement filter for use in room fronts with 2 round control openings ONLY • Washable/reusable nylon mesh filter • Order individually or by box of 20 • Used for standard or high-mount models RAA72A Replacement Filter for Rounded-Front “J” Chassis for A, B and C Series and D Series ending in “1” or “2” (2001–2011) • Replacement filter for use in room fronts with oval control pushbutton openings ONLY • Washable/reusable nyl
THERMOSTATS – HEAT PUMP RAK148D1 (A-B, AZ, 35, 38, 39, 55, 58, 61, 75, 85 and AZR Series*) Heat Pump Digital Remote Thermostat • 24V AC digital remote wall thermostat with single-stage cooling and 2-stage heating for heat pump models • Requires 6-wire hookup RAK148P1 (A-B, AZ, 35, 38, 39, 55, 58, 61, 75, 85 and AZR Series*) Heat Pump Programmable Remote Thermostat • 24V AC programmable remote wall thermostat with single-stage cooling and 2-stage heating for heat pump models • Programmable for 7-day or 5+2-
THERMOSTATS – ELECTRIC RESISTANCE HEAT RAK164D1 (A-B, AZ, 25, 28, 29, 41, 75, 85 and AZR Series*) Cooling with Electric Heat Digital Remote Thermostat • 24V AC digital remote wall thermostat with single-stage cooling and single-stage heating for resistance heat models • Requires 5-wire hookup RAK164P1 (A-B, AZ, 25, 28, 29, 41, 75, 85 and AZR Series*) Cooling with Electric Heat Programmable Remote Thermostat • 24V AC programmable remote wall thermostat with single-stage cooling and single-stage heating for
ORDER INFORMATION Vertical Zoneline® units Number RAK3152 RAK3202 RAK3302 RAK4157 RAK4207 RAK4307 RAK5157 RAK5207 RAK5307 RAVAL1 RAVRG1 RAVRG2 RAVRMS RAVWP6 RAVWP8 RAVWP12 RAVWP15 Description 208/230V Universal power supply kit (15 Amp) 208/230V Universal power supply kit (20 Amp) 208/230V Universal power supply kit (30 Amp) 208/230V Universal power supply kit (15 Amp) 208/230V Universal power supply kit (20 Amp) 208/230V Universal power supply kit (30 Amp) 265/277V Universal power supply kit (15 Amp) 265/
ORDER INFORMATION Zoneline units Number RAK205CW RAK204D15P RAK204D20P RAK204D30P RAK204E15 RAK204E20 RAK204E30 RAK204U RAK601 RAK602 RAK605 RAK6052 RAK7012 RAK7022 RAK8022 RAK8023 RAK806 RAK901L Description Chaseway for RAK204U sub-base 230/208V, 15 amp standard sub-base with power cord 230/208V, 20 amp standard sub-base with power cord 230/208V, 30 amp standard sub-base with power cord 265V, 15 amp standard sub-base 265V, 20 amp standard sub-base 265V, 30 amp standard sub-base Standard sub-base without e
ORDER INFORMATION Thermostats Number RAK148D1 RAK148P1 RAK164D1 RAK164P1 Description Heat pump digital remote thermostat Heat pump programmable remote thermostat Cooling with electric heat digital remote thermostat Cooling with electric heat programmable remote thermostat SERVICE AND SUPPORT For builder resources and support visit: buildwithge.com or call 800.GE.CARES For product information and service visit : geappliances.com or call 800.626.2000 Page No.
WHY GE? GE’s commitment to appliances has never been stronger. Backed by an investment of more than $1 billion, that legacy continues. We’re streamlining our manufacturing. Conducting more consumer research. Launching new product innovations. Creating more U.S. jobs. Advertising on a national scale. And delivering the support our partners need to succeed well into the future. The opportunity for growth has never been so promising. We’re not just imagining. We’re doing.