Owner's Manual & Installation Instructions

8 49-5000517 Rev. 2
Configuration mode
The configuration mode is used to set the thermostat to match
the heating/cooling system. This thermostat will function with
up to 2-stage heatpump systems. To configure the thermostat,
perform the following steps:
NOTE: Operation being set will blink in the display.
1. Slide the Function switch to the OFF position.
2. Simultaneously hold the
<
and
>
buttons in
for 6 seconds while the thermostat is in OFF mode.
3. Press the
<
or
>
button to change settings within
each screen.
4. Press the Hold button to advance to the next screen.
Note: The Mode button will return you to the previous screen.
5. To save the changes and exit configuration mode, slide the
Function switch to Heat or Cool.
Configuration Mode Settings
The setup screens for Configuration Mode are as follows:
1. Temperature Scale (F or C)—Choose
Fahrenheit or Celsius.
Press the
<
or
>
button
to select.
Press the Hold button to advance to the next screen.
NOTE: Default factory setting is Fahrenheit.
2. Heat System—Check model number on the GE PTAC
chassis to determine the primary heating method.
AZ65H/95H***** are heat pumps and is the thermostat factory
setting.
AZ45E/95E***** are electric heat models and will require a
mode setting change.
To change the heating mode configuration, press the
<
or
>
button. Select HPb screen for heat pump or select ELE
screen for electric heat.
Press the Hold button to advance to the next screen.