Corrosion & Erosion
19
• Insulation and reproong can accumulate
moisture and cause accelerated corrosion
• Breaches of weather jacketing increases with age
and mechanical damage
• Extensive stripping and abatement needed for
visual testing and ultrasonic testing
• Digital X-ray can give general condition a specic
thickness in recordable format for prioritization of
additional inspection/remediation can be scheduled.
• See pages 11 - 12 for general description
• Heat exchanger tube problems can cause unit
outages and environmental impact
• Damage can occur suddenly (titanium tube
support plate wear after 2 weeks of above design
ow conditions) or longer term
• RVI can provide internal condition. Leak testing
does not provide volumetric assessement
• ET is preferred method of tube inspection for non-
ferrous alloys
• See page 13 for general description
• Hydrogen damage can be caused by condenser in
leakage and failures can lead to unit outages
• External UT/EMAT scanning can be used to identify
suspected areas of wall loss
• RVI can rapidly conrm external inspections for
exact location and severity of boiler tubes for ID
damage
• See pages 7 - 8 for general description
Corrosion Under Insulation/Fireproofing
Radiographic Testing (RT)
Heat Exchanger Damage
Eddy Current Testing (ET)
Boiler Tube Hydrogen Damage
Remote Visual Inspection (RVI)
Industrial environments will promote signicant corrosion
of carbon steel piping components
Heat exchanger tubing can suer specic damage that
can be precisely qualied by ET
Localized corrosion damage in carbon steel can be con-
rmed using visual methods