Brochure

Corrosion & Erosion
23
Instrument Penetrations have caused signicant
reliability concerns at nuclear plants
Dicult access and need for detailed inspection
data required multi-modal approach for proper
integrity assessment
Combination of RVI, UT and Eddy Current tech-
niques help assess BMI guide tubes to prioritize
need for repair
See Pages 7 - 10 and 13 for general description
Reactor Euent Air Coolers have suered numer-
ous Erosion/Corrosion incidents due to Ammonium
Bisulde erosion and Ammonium Chloride corro-
sion
Rigorous monitoring of operating conditions must
be followed by extensive UT and RT surveys
Rightrax installed sensors allow continuous or
intermittent monitoring of suspect areas
See Pages 15 - 18 for general description
Extended downtimes and idle service water sys-
tems have promoted microbiological corrosion
MIC can be highly localized and cause complete
penetration in short time periods
Use RVI or RT or both in complementary mode
See Pages 7 - 10 and 13 for general description
Bottom Mounted Instrumentation (BMI)
Remote Visual Inspection/Ultrasonic Testing (RVI/UT)
Hydro-Processor Effluent Air Cooler
Rightrax Installed Sensor (UT)
Service Water Piping Corrosion
Remote Visual Inspection/Ultrasonic Testing (RVI/UT)
Bottom mounted Instruments present a challenge for
mechanical Integrity assessment.
REAC pipe condition can be continuously assessed regard-
less of process service conditions in typical operation
MIC can be highly localized and cause penetration in a
short period of time