Operating Manual

GE
Sensing & Inspection Technologies
Rightrax LT Specications
Online Corrosion Monitoring System
M2 Sensor
Sensor type
14-element linear array
Nominal frequency
8.0 MHz
Operating mode
Pulse Echo
Typical Measuring
Range
5 - 100 mm (0.196 - 3.9”) on smooth parallel surfaces.
Minimum measurable thickness depends on internal wall damage mechanism.
Measurement area
200 mm x 12 mm (7.87 x 0.47”)
Couplant
Acoustic Tape
Mounting
Permanent xing by acoustic tape and epoxy putty
Cabling 1.5 m (4.9 ft) with Lemo or BNC connector
Extension cable up to a maximum of 70 m (230 ft)
Housing
Stainless Steel 316L
Ingress rating
IP56 equivalent
Dimensions Main housing: 83 x 70 x 35 mm (3.27 x 2.76 x 1.38”)
Flexible strip: 244 x 55 mm (9.61 x 2.17”)
Weight
0.50 kg (1.1 lb)
Certication
ATEX Zone 2
Temperature range
-40°C to 120°C (-40°F to 248°F)
Rightrax LT System
Thickness repeatability ± 0.1 mm
(0.0039”)
The repeatability of the thickness reading through the complete system is the smallest change that can be
reliably detected.
Thickness accuracy Accuracy depends on knowing the substrate material sound velocity. Calibration standards or material
specications of the material are required for accurate results. This accuracy applies for uniform surfaces. Highly
localized pitting may not be detected.
Thickness resolution -
single reading
± 0.01 mm
(0.0039”)
Total number of sensors
per attached data logger
10
Total number of data
loggers per line driver
2 Each driven by a 10-way multi-core cable with a maximum length of 260 m (853 ft)
Maximum total number
of sensor extension
cable per system
450 m (1476 ft)
An individual sensor can have up to 70 meters of extension cable, but the total length of extension cable for the
whole system cannot exceed 450 m (1476 ft).
www.gesensinginspection.com
© 2010 General Electric Company. All Rights Reserved. Specications subject to change without notice.
GEIT-20211EN (05/10)

Summary of content (1 pages)