Product Brochure

3 Residential Electronic Circuit Interrupters
Features
Our DFCI has useful features for
assisting you or your electrician
in troubleshooting a trip. Should
the DFCI trip, the LED inside the
trip flag window will indicate the
last known trip condition when the
breaker is reenergized as shown in
the chart below.
Push to Test
GE’s two position push to test
allows verification of the AFCI and
GFCI protection independently.
It’s also a good way to practice
observing the LED indications
covered below.
LED
Color Pattern
Last known
trip condition
Orange Overload
Orange-Red Ground fault
Orange-Yellow Arc fault
Specifications
Combination Arc Fault
Circuit Interrupter
Class A 5mA Ground Fault
Circuit Interrupter
• 120VAC, 60 Hz
• Wire Range #14-8 AWG
UL Listed Arc Fault Circuit
Interrupters No. 1699
UL Listed Ground Fault
Circuit Interrupters No. 493
UL Listed Molded Case
Circuit Breakers No. 489
Catalog Number
Plug-in Amps Poles Volt
Interrupting
Rating AIC
Standard
Pack
Long Pig Tail
THQL1115DF 15
1 120 Vac
10k
10
THQL1120DF 20
THHQL1115DF 15
22k
THHQL1120DF 20
Short Pig Tail
THQL1115DFS 15
1 120 Vac 10k 10
THQL1120DFS 20
Arc fault test
Ground fault test