1
, Main Lugs Factory Installed
Outdoor (NEMA 3R) Enclosure
Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size
Ampere 1” 1” 1” 1-pole Feed Box (AWG/kcmil) Equipment Product List Price
Rating Spaces Spaces Spaces Spaces Type Number Cu-Al Ground Kit Number GO-137
125 12 6 4 12 Top R3 6-2/0 TGK12 (order separately) TL12412R
2,4
$316.00
TGK24 (order separately)
150 18 8 6 18 Top R4 1-3/0 (Cu), TGK24 (order separately) TL18415R
2,4
$411.00
2/0-3/0 (Al) TGK32 (order separately)
150 24 12 8 24 Top R4 1-3/0 (Cu), TGK24 (order separately) TL24415R
2,4
$530.00
2/0-3/0 (Al) TGK32 (order separately)
200 18 8 6 18 Top R4 1-250 (Cu), TGK32 (order separately) TL18420R
2,4
$478.00
2/0-250 (Al)
200 30 14 10 30 Top R6 1-250 (Cu), TGK32 (order separately) TL30420R
2,4
$550.00
2/0-250 (Al)
200 42 20 14 42 Top R8 1-250 (Cu), TGK42 (order separately) TL42420R
2,3
$929.00
2/0-250 (Al)
225 42 20 14 42 Top R8 1-300 (Cu), TGK42 (order separately) TL42422R
2,3
$996.00
2/0-300 (Al)
1
Also UL Listed for three-phase, four-wire 240/120 Volts ac delta and three-phase, three-wire 240 Volts ac branch breakers installed.
2
100-200 Amp three-phase devices have removable closing cap. Larger Ampere devices require field cut openings. Order hubs separately. See page 1-27.
3
Not suitable for use as service entrance equipment.
4
Alternate main breaker: 100 Amp max. THQL three-pole, use retainer THQLRK. See page 1-28.
Three-Phase, Four-Wire, 208Y/120 Vac
5
, Main Breaker Factory Installed
Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size
Ampere 1” 1” 1” 1-pole Feed
2
Box (AWG/kcmil) Equipment Product List Price
Rating Spaces Spaces Spaces Spaces Front Type Type Number Cu-Al Ground Kit Number GO-137
100 12 6 4 12 Combination Top 6 6-1/0 (Cu), TGK12 (order separately) TM12410C
6
$497.00
Flush/Surface Bottom 4-1/0 (Al) TGK24 (order separately)
Front
100 18 8 6 18 Combination Top 6 6-1/0 (Cu), TGK24 (order separately) TM18410C
6
$669.00
Flush/Surface Bottom 4-1/0 (Al) TGK32 (order separately)
Front
125 30 14 10 30 Combination Top 11 1-3/0 (Cu), TGK32 (order separately) TM30412C $1324.00
Flush/Surface 2/0-3/0 (Al)
Front
125 30 14 10 30 Combination Bottom 11 1-3/0 (Cu), TGK32 (order separately) TM30412CB $1324.00
Flush/Surface 2/0-3/0 (Al)
Front
150 24 12 8 24 Combination Top 11 1-3/0 (Cu), TGL1, TGL2, TGL20,TNG3, TM24415C $1277.00
Flush/Surface 2/0-3/0 (Al TGN6 (order separately)
Front
150 24 12 8 24 Combination Bottom 11 1-3/0 (Cu), TGK32 (order separately) TM24415CB $1277.00
Flush/Surface 2/0-3/0 (Al)
Front
150 30 14 10 30 Combination Top 11 1-3/0 (Cu), TGK32 (order separately) TM30415C $1324.00
Flush/Surface 2/0-3/0 (Al)
Front
150 30 14 10 30 Combination Bottom 11 1-3/0 (Cu), TGK32 (order separately) TM30415CB $1324.00
Flush/Surface 2/0-3/0 (Al)
Front
150 42 20 14 42 Combination Top 13 1-3/0 (Cu), TGK42 (order separately) TM42415C $1521.00
Flush/Surface 2/0-3/0 (Al)
Front
150 42 20 14 42 Combination Bottom 13 1-3/0 (Cu), TGK42 (order separately) TM42415CB $1521.00
Flush/Surface 2/0-3/0 (Al)
Front
200 24 12 8 24 Combination Top 11 1-300 (Cu), TGK32 (order separately) TM24420C $1275.00
Flush/Surface 2/0-300 (Al)
Front
200 24 12 8 24 Combination Bottom 11 1-300 (Cu), TGK32 (order separately) TM24420CB $1275.00
Flush/Surface 2/0-300 (Al)
Front
5
Also UL Listed for three-phase, four-wire 240/120 Volts ac delta and three-phase, three-wire 240 Volts ac branch breakers installed.
6
100 Amp indoor devices UL listed for bottom-feed by installing complete unit upside-down.
Note: See page 9-15, AL Series Lighting Panelboards as replacements for 300-600A load centers.