Installation Guide
REMOVE BACK PANEL
A. Remove all ice if applicable.
B. Drain reservoir by removing reservoir drain
cap. Replace cap when water has drained.
C. Remove the screws from the back panel
(19 for gourmet cube models; 15 for nugget
models).
REMOVE FRONT PANELS
A. Open the ice machine door all the way.
B. Remove the Service Panel.
C. Remove the Kickplate by removing the 2
screws securing it to the base.
REMOVE EXISTING DRAIN HOSE
Remove the existing drain hose. The drain hose
is the white tube with a white snap fit clamp
on it in the upper left hand corner of the side
service panel access area. Save the snap fit
clamp. It will be used to install the new drain
hose.
Installation Instructions
INSTALLING PUMP KIT
1
2
3
4
DISCONNECT ELECTRICAL POWER
Service Panel
Kickplate Screws
(Gourmet Cube
Machine Shown)
Drain Cap - Gourmet Cube Model
Drain Cap - Nugget Model
2
1
Existing Drain Hose
Snap Fit Clamp
2
D. Remove the side service panel. Pull out on the
left side (1) and back (2) to remove.
UCC15
Gourmet
Cube Model
Screw
Locations
UNC15
Nugget Model
Screw
Locations
Electrical Shock Hazard
Death or serious injury can result from failure to
follow these instructions.
• Service by a qualified service technician only.
• Disconnect power before servicing this product.
• Reconnect all grounding devices after service.
• Replace all parts and panels before operating.
WARNING