Installation Instructions

31-5000486 Rev. 2 13
Installation Instructions
Electrical Requirements
Model Power Supply Recommended breaker
size (A)
UUY24ZGDAA
UUY36ZGDAA
UUY48ZGDAA
UUY60ZGDAA
208/230V-1Ph-60Hz 15
Control wiring” to “Electric wiring
Using 18 Gauge Solid Core Copper Wire
1. Cut back the insulation 1” from the end of the wire.
2. Remove the screw from the terminal block, and wrap
the wire around the screw.
3. Return the screw and wire to the terminal block and
tighten securely.
Jacket / Insulation
1” (25mm)
Stranded Wire
1. Cut back the insulation 3/8” from the end of the wire.
2. Make sure the round or forked terminal connector is
rated for the amperage of the unit being installed.
3. Use a crimping tool only to fasten the connector to the
wire.
4. Return the screw and connector to the terminal block
and tighten securely.
Solderless
Terminal
3/8” (10mm)
Wiring Connections
1. High and low voltage wires should be led through
different rubber rings of the electric box cover.
2. To avoid communication errors, maintain as much
separation as possible between the power and control
wiring.
3. High and low voltage wires should be secured
separately. Secure the former ones with large clamps
and the latter ones with small clamps.
4. Use screws to tighten high and low voltage wiring on
the terminal board. Improper connection may create a
fire hazard.
5. Ground the units by connecting the ground wire.
6. All wiring must comply with local and national code.
Screw with
Special Fastener
Round
Terminal
Wire
Terminal
Board
Duct System
CAUTION
1. Ensure that the power supply is disconnected prior to
installing the heater kit.
2. A means of strain relief and conductor protection must
be provided at the supply wire entrance into cabinet.
3. Only use copper conductors.
4. Installation must follow The National Electrical Code
and other applicable codes.
5. If this appliance is installed in an enclosed area, such
as a garage or utility room with any carbon monoxide
producing appliance, ensure that area is properly
ventilated to the outside.