Installation Guide

31-7000188 Rev. 0 19
C3. USE TOP CABINET TEMPLATE FOR
PREPARATION OF TOP CABINET
You need to drill holes for the top support screws and a
hole large enough for the power cord to fit through.
• Read the instructions on the TOP CABINET TEMPLATE.
• Tape it underneath the top cabinet.
Drill the holes, following the instructions on the TOP
CABINET TEMPLATE.
CAUTION
Wear safety goggles when drilling
holes in the cabinet bottom.
C4. REMOVE BLOWER PLATE
Remove and save the screw that holds the blower
plate to the microwave. Lift off the blower plate.
The cover plate is installed with the blower plate and
does not need to be uninstalled.
C5. ADAPTING MICROWAVE AIR DIRECTOR
FOR OUTSIDE BACK EXHAUST
1. Carefully pull out the AIR DIRECTOR.
2. Rotate the air director counterclockwise 180°.
3. Remove the knockout plates in the back of the
microwave with snips. (For some models).
Knockout Plates:
Snip all 4 web on
each knockout panel
and remove the metal
knockouts for rear airflow.
Please take care to
remove any sharp edges
created from removing the
knockout plates.
Installation Instructions
A
C
D
B
2. INSTALLATION TYPES (Choose A, B or C)
Before:
Openings Facing
Forward
Air Director
Before Rotation After Rotation
Back of Microwave
Blower Plate
Cover Plate
Back of
Microwave