Installation guide

Installation Preparation
DRAIN REQUIREMENTS
Follow local codes and ordinances.
Do not exceed ] 0 feet distance to drain.
To prevent back flow into the dishwasher, COlmect
drain line to an air gap or use a 30" high drain loop,
depending on local codes.
Air gap in ust be used when waste tee or disposer
COlmectioi_ is less than 18" above the floor to prevent
siphoning.
DETERMINE DRAIN METHOD
The type ot drain iI_stallati(m depends (m the fl)llowing
questions.
Do local codes or ordii_ances reqtlii'e an aii" gap?
Will waste tee or disposer COlmectioi_ be less than 18"
above the floor?
Will installation have a high drain loop less than 30"
above the floor?
If the answer to ANYof these questions is YES, Method 1
MUST be used.
If all answers are NO, either inethod inay be used.
.M_ air gap MUST BE USED if the drain hose is con-
nected to a waste tee or disposer lower than 18" above
the floor level.
Faihu'e to provide the proper drain COlmectioi_ using
an air gap or a 30" rain. high drain loop will result in
ilnproper drailfing of the dishwasher which inav cause
damage or poor wash peril)finance.
Method 1 - Air Gap with Waste Tee or Disposer
An air gap must be used when the waste tee or disposer
connection is less than 18" from the floor.
Method 2 - High Drain Loop with Waste Tee or
Disposer Install waste tee or disposer and air gap according
to manufacturer's instructions.
l-
CABINET PREPARATION
Drill a 1-1/9" dia. hole in the cabinet wall within
the shaded areas shown for the drain hose Colmec-
tion. The hole should be Slnooth with no sharp
edges.
ll DOlT YAVOIR tree coupure ai_tirefl)ulemei_t si le
ttlvat! de vidange est branch6 sur un raccord d'6gout ou
tin broyeur d'ordures a inoins de 46 cln (18 po) du sol.
Si la vidange n'est pas branch_e correctement en
utilisant tree coupure ai_tirefoulelnei_t ou tm boucle
d'_gout d'au moins 76 Cln (30 po) de haut,
l'_coulemei_t de l'eau du lave-vaisselle n'est pas boil
ce q ui petit causer des dolmnages ou tm inauvais
lavage de la vaisselle.