Manual

The Problem Solver
Ouldoor/I_door H_/rigeralor
Questions ?
Use this
problem
solver/
PROBLEM POSSIBLE CAUSE
APPLIANCE
DOES NOT OPERATE
VIBRATION OR
RATTLING (Slight
vibration is normaL)
COMPRESSOR
MOTOR OPERATES
FOR LONG PERIODS
OR CYCLES ON AND
OFF" FREQUENTLY
COMPARTMENT
TO O WARM
APPLIANCE
HAS ODOR
DOOR
NOT CLOSING
PROPERLY
MOISTURE FORMS
ON OUTSIDE OF
APPLIANCE
FROST OR MOISTURE
COLLECTS INSIDE
Appliance is so quiet that most of the time vou will hear low or
no operating noise.
Appliance may be in defl'ost cycle when compressor motor does not
operate ti)r about 30 minutes.
Controls are set to OFE Press ON/OFF button on control panel.
If interior light is not on, appliance may not be plugged in at
electrical outlet. Push the plug completely into the electrical outlet.
The GFCI circuit breaker is tripped. Replace fllse or reset
the breaker.
The appliance is in showroom mode. Unplug it and plug it back in.
Ac!iust the lexeling legs as shown in the Installation Instructions.
Normal when appliance is first plugged in. X4'ait 24 horn's for the
appliance to completely cool down.
Often occurs when large amounts of ti)od are placed in appliance.
This is normal.
Door left open or package holding door open.
Hot weather or frequent door openings. This is normal.
Temperature control set at the coldest setting.
See Temperature Control.
Temperature control not set cold enough. See Temperature Control.
Allow 12-24 horn's ti)r temperature to change.
_4'arm weather or frequent door openings.
Door left open fi)r long time.
Package may be holding door open.
Them/istor may be blocked, which can affect the overall temperatm'e.
The themfistor is locamd on the fight hand side just above the third shell
Interior needs cleaning. See Care and Cleaning.
Kee I) open box of baking soda in appliance; replace everv 3 months.
Door gasket is sticking or folding over. Apply petroleum.jelly
or parattin wax to the tace of the gasket.
The door is hitting an internal component inside the appliance.
At!justinterior components to prevent interference.
Not tlntlStlal dm'ing periods of high humidity. X4]I)e stlrt_lce dI'>
Door left open or package holding door open.
Too freqtlent or too long door ol)enings.
In humid weather; air carries moisture into appliance when door
is opened.
Temperature control is set at coldest setting.
Them_istor may be blocked, which can affect the overall temperature.
The themfistor is located on the fight hand side just above the third shell
17