Installation guide

Design Guide
THE INSTALLATION SPACE
23-3/4"
34-1/2"
NOTE:
Handleand
handlestandoff
depthis2-3/4"
Free-Standing- Usecanopytop Built-In - Removecanopytop
(if needed)
Choose the location:
This product has been designed as a free-standing
unit; however, if desired, it may also be built-in.
These products may be closed ill on the top and
three sides as long _ls tile fl'ont is unobstructed fl>i"
air circulation and proper access to tile door.
Do not operate these products where the temllerature
will go below 45°F (7°C) or above 190°F (49°C).
Unit must be installed on a stiucturallv sound and
level surfilce strong enough to support a fldly loaded
refligeratm; or approx. 250 lbs.
24"
The cutout depth should be 24"
Tile cutout dimensions shown allow for a fidl door
swing and access to the pull-out racks when installed
ill standard 24" deep cabinets.
Tile Outdoor/Indoor Refrigerator can be installed
fl'ee-standing,
If installing between frameless cabinets, a l/2" wide
filler strip or side panel may be required on tile
hinge side, The filler strip will act as a spacer between
tile case and a(!jacent cabinet door swing. Tile width
of the opening must include the filler panels.
NOTE: Ill a standard 24" opening, the door will
protrude l-I/2" fin'ward of tile surrounding cabinets.
Additional Specifications
A 120 volt 60Hz., 15 or 20 amp power supply is
required. All individual properly grounded branch
circuit or circuit breaker is recomn]ended. Install a
properly grounded 3-prong electrical receptacle
recessed into the back wall as shown, Electrical must
be located on rear wall as shown. THIS PRODUCT
MUST BE CONNECTED TO A POWER SOURCE
WITH GROUND FAULT CIRCUIT INTERRUPTER
(GFCI) PROTECTION WHEN INSTALLED IN AN
OUTDOOR LOCATION. LOCAL CODES MAY
REQUIRE A SEPARATE CIRCUIT.
PRODUCT CLEARANCES AND
LOCATION REQUIREMENTS
Tile Outdoor/Indoor Refligerator is factory set fin"
a l l 0° door swing.
When installed in a corner:
Allow 5-1/4" rain. clearance on tile hinge side tor tile
90 ° door swing and to allow racks to slide out.
Allow 15" n]ininmln clearance on tile hinge side tor
a fldl 110 ° door swing.
Test tile door swing. Carefull) open and close tile (tooi:
Tile door should not rtlb or catch on ac!jacent cabinet U.
Ac!iust if the door makes contact with cabinet U.
15"Minimum
to Wall
, 110° [
Door
Swing
i
I
'\,, \\\\
110° .. ,
Swing!;
\ ii 23-5/8"
- _ 4,-L; -
5-1/4" Minimum
to Wall
4
PREPARATION FOR BUILT-IN
UNDER-COUNTER INSTALLATIONS
ONLY
Tile top canopy may be removed when installing under
a COtlntertol).
I/elnove tile three screws ti'oln tile back of tile top
canoI)y CA).
Using heavy-du V work gloves, lift up on tile top
canopy back (B) and slide it torward until it unlatches
fl'oln the unit ((:).
iJfl tile top canopy up and ott' of tile tlnit.
NOTE: Kee I) the top canopy and screws tot future
free-standing installations.
NOTE: When installing the unit ill a flee-standing
configuration, tile top canopy inust be leli ill place.
If replacing the top canopy inake sure the three latches
ill tile fl'ont slide into tile fl'ont lip of tile canopy betore
pushing file canopy to the rear of the unit.
(B)
CA)
CAUTION:
Undersideedges
of the stainless (C)
steelcanopytop
maybesharp.
Wearheavy-duty
workgloveswhen
movingthe top.