BEFORE YOU BEGIN
Readthese instructions completely and carefully.
• IMPORTANT-Savethese instructions for local
inspector's use.
• IMPORTANT-Observeallgoverningcodesand
ordinances.
• Note to Installer- Besure to leave these instructions
with the Consumer.
° Note to Consumer- Keepthese instructions
with your Owner's Manual for future reference.
• Completion Time- i to 3 hours.
• Properinstallation is the responsibility of the installer.
Productfailure due to improper installation isnot covered
under the warranty. SeeOwner's Manualfor warranty
information.
- WARNING:
Thisappliance must be properly grounded. See"Electric
Supply."
For Monogram localservice in your area,1.800.444.1845.
For Monogram Servicein Canada,call 1.800.561.3344.
For Monogram Partsand Accessories,call 1.800.626.2002.
If you receiveda damaged range, you should contact your
dealer.
In the Commonwealth of Massachusetts:
• Thisproduct must be installed by a licensedplumber or gas
fitter.
• When using balltype gas shut off valves,they shall be
T-handle type.
• A flexible gas connector,when used,must not exceed
3feet.
-AWARNING:
All ranges can tip. Injury could result. Install the
supplied Anti-Tip Bracket provided. See instructions
in this manual or with the bracket.
If soldoutside the U.S.and Canada:
-AWARNING:lfyouwishtouse this product with
Liquefied Petroleum (LP)gas containing greater than 10%
butane, you must purchase the butane conversion kit
#WB28K10589. To order, please call 1.888.664.8403
or 1.787.276.4051.
Vent hood Combinations:
It is recommended that these ranges be installed
in conjunction with a suitable overhead vent hood.
• Install a hood with at least 1200CFMabove a 48"
wide range.
• Install a hood with at least600 CFMabove a 30"
or 36" range.
Dueto the high heat capacity of this unit, particular attention
should be paid to the hood and ductwork installation to
assure it meets local building codes.
-AWARNING:
Clearancesto horizontal surfaces above the range,
measured to the cooking surface:
• Installations without a hood require 48" minimum
to combustibles.
• A custom hood installation with exposedhorizontal
combustibles surfaces must have an Auto-On feature.
• For other installationswith a hood, refer to hood installation
instructions for specifichood clearances.
- CAUTION:
Theseranges weigh up to 700 pounds. Somedisassembly
will reduce the weight considerably. Due to the weight and
sizeof the range and to reduce the riskof personal injury
or damage to the product:
TWOPEOPLEAREREQUIREDFORPROPERINSTALLATION
OF36" AND 30" RANGES.
THREEPEOPLEAREREQUIREDFORPROPERINSTALLATION
OF48" RANGES.
Leaktesting of the appliance shallbe conducted according
to the manufacturer's instructions.
Installation must conform with local codes. In the absence
of local codes,the range must comply with the National Fuel
Gas Code,ANSIZ223.1/NFPA54, latest edition and National
ElectricalCode ANSI/NFPA70 latest addition. In Canada,
installation must conform with the current Natural Gas
Installation Code,CAN/CGA-B149.1or the current Propane
Installation Code,CAN/CGA-B149.2,and with local codes
where applicable.Thisrange has been design-certified by
CSAInternational according to ANSIZ21.1,latest edition and
Canadian Gas Associationaccording to CAN/CGA-I.1latest
edition.