Installation guide

Installation Instructions
IB-1ElectricalConnections
ATTENTION INSTALLER!!!
All electric wall ovens must be hard wired
(direct wired) into an approved junction
box. A plug and receptacle is NOT IR21
permitted on these products.
I--I
Do not shorten the flexible conduit.The
conduit strain Relief Clamp must be securely
attached to the junction box and the flexible
conduit must be securely attached to the
clamp. If the flexible conduit will not fit within
the clamp, do not install the oven until a
clamp of the proper size is obtained.
NOTE TO ELECTRICIAN: The 3 power leads
supplied with this appliance are UL recognized for
connection to larger gauge household wiring. The
insulation of these 3 leads is rated at temperatures
much higher than the temperature rating of house-
hold wiring. The current carrying capacity of the
conductor is governed by the temperature rating of
the insulation around the wire, rather than the wire
gauge alone.
WARNING: Improper connection ofaluminum house wiring to copper
leads can result in an electrical
hazard or fire. Use only connectors
designed for joining copper to aluminum
and follow the manufacturer's
recommended procedure closely.
i
Turn off the circuit breaker or remove fuses
to the oven branch circuit.
With the oven in front of the cabinet
opening, on a table or platform, connect the
flexible conduit to the electrical junction box
as shown below. You will need to purchase
a strain relief clamp to complete the
connection of the conduit to the junction
box.
JUNCTION BOX
PLACE OVEN ON
A SUPPORT
TO ASSIST IN
CONNECTING
CONDUIT
STRAIN RELIEF CLAMP
NOT INCLUDED )
AT JUNCTION BOX
8 ( Continued on Next Page)