Installation Instructions 30" Convection Built-In Ovens Models: ZET1038 ZET1058 0 Monogram: We bring good things to life.
Installation Instructions BEFORE YOU BEGIN Read these instructions and carefully. _ completely IM PORTANT- Save these instructions for local inspector's use. III n I'_£_ I_'I'AI_ wall ovens and to reduce the risk of personal injury or damage to the product, TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION. i-r llVlrunl/_l_ll- Observe a_lgoverning _ codes and ordinances. Note to Installer - Be sure to leave these instructions with the Consumer.
Installation Instructions CONTENTS Installation Preparation Electrical Requirements ...................................................7 Tools and Materials ......................................................... 7 Product Information Product Dimensions ..........................................................3 Provide Oven Supports .....................................................8 Step 1, Remove Packaging .............................................
Cabinetry Framed Cabinet, Framed Single oven _- I23-1/2" 1 I 28" Min. 28-3/8" Max. Double Oven 30"_23-1/2%' / Inside I 28"Min. 28-3/8"Max. 47-5/8" Min. 47-3/4" Max. Order a 30" oven cabinet with the cutout sized to fit the double oven. • These ovens require 3/4" overlap on both sides. Allow 1" Min. for top overlap and clearance to upper doors. Allow 1/4" clearance atthe bottom. • Installing a double oven 12"from the floor will place the base of the upper oven at countertop level.
Cabinetry Installation Single Oven Over a Monogram Warming Drawer Double Oven 23-1/2" Min, _lnside_ 2x2 or 2x4 Anti-Tip Block Against Rear _Wall, 9" From Floorto Bottom of Block 2x2 or 2x4 Anti-Tip Block Against Rear Wall, 9" From Floor to Bottom of Block 47-5/8" Min. 47-3/4" Max. 2" Min. _'AIIow 5/8" Overlap on All Sides 1" Min. Above Toekick or Adjust to Oven Installation Height Note: Install the oven only with specific models listed on the label located on top of the oven.
Cabinetry Installation Monogram Below a Advantium Oven Installation Between Monogram Advantium a Warming Drawer a Oven and 23-1/2" Min. _lnside _,,_ 2" Min. 2" Min. 45-1/4" Note: Install the oven only with specific models listed on the label located on top of the oven. 2" Min. 45-1/4" 1" Min. Above Toekick NOTE: Additional clearances may be required. Check to be sure the oven supports above the Warming Drawer does not obstruct the required interior 23-1/2" depth and 9-1/4" height.
Installation ELECTRICAL Preparation REQUIREMENTS TOOLS and MATERIALS YOU WILL NEED These Monogram built-in ovens require a separate properly grounded 3-wire 120/208 or 120/240 volt, 60 Hz power supply, protected by a time delay fuse or circuit breaker. • Double ovens are rated at 6.5 KW at 240 volt and 6.5 KW at 208 volt. • Single ovens are rated at 3.3 KW at 240 volt and 2.8 KW at 208 volt. • Ovens are supplied with a flexible power cable which must be attached to a junction box.
Installation Preparation PROVIDE OVEN SUPPORTS ISTEP 11 REMOVE Ovens may be supported by either a solid bottom or by 2 x 4 runners. • The support must be level and rigidly mounted, flush with the bottom edge of the cutout. _2"x • Remove the carton, plastic coverings and styrofoam side/corner posts. • To prevent damage to the floor, do not remove the styrofoam base until the oven is ready to be installed. • Remove oven contents, shelves and packaging.
Installation Preparation • If a cold water pipe is interrupted by plastic, nonmetallic gaskets, union connections or other insulating materials, DO NOT use for grounding. • DO NOT ground to a gas pipe. • DO NOT have a fuse in the NEUTRAL or GROUNDING circuit. A fuse in the NEUTRAL or GROUNDING circuit could result in an electrical shock. ELECTRICAL SHOCK HAZARD The electrical power to the oven branch circuit must be shut-off while line connections are being made. WARNING • Use copper wiring only.
Installation [STEP Instructions SKIP THIS STEP IF YOU ARE CONNECTING TO 240 VOLT POWER SUPPLY. 208V ELECTRICAL SUPPLY WARNING If connecting to a 208 volt, 60 HZ supply, a jumper must be used across two terminals. These ovens are pre-wired for connection to 240 volt, 60 HZ, supply. If connecting to a 208 volt supply, modifications must be made. • For double ovens, there are two jumpers, one for the upper oven, one for the lower oven. • For single ovens there is one jumper.
Installation Instructions REMOVE OVEN DOOR(S) [STEP 51 ROUTE CABLE THROUGH CUTOUT • Open the door fully. • Push hinge latches up to lock hinges in open position, CAUTION 0ven(s) are very heavy. 2 people are required to lift oven(s) into the opening. Ovens have side handles, Grasp side handle with one hand and put other hand into the oven opening. Carefully, lift the oven to the cabinet opening. Hinge Latch PRUDENCE Le four est Iourd.
Installation Instructions ISTEP 61 SECURE OVEN TO CABINET I STEP 7_ REPLACE OVEN DOOR • Grasp door firmly on both sides. • Slide the hinge slots in the bottom of the door over the hinges. • Push the door all the way in, against the oven. • Slide oven into cabinet opening. • Drill 3/32" pilot holes through the oven front frame and into the cabinet frame. / • Secure oven to cabinet with screws provided. Single ovens use 2 screws, one on each side. Double ovens use 4 screws, 2 on each side.
Installation [STEP CONNECT Instructions ELECTRICAL ELECTRICAL SHOCK RISQUE DE CHOC I_LECTRIQUE HAZARD • Electrical ground is required on this appliance • DO NOT connect to the electrical • Cet appareit dolt _tre mis _ la terre. • NE PAS brancher l'alimentation WARNING AVERTISSEMENT supply until appliance is permanently grounded. _lectrique si l'appareil n'est pas • Disconnect power to the junction box before making the electrical connection.
Installation INSTALLATION Instructions CHECKLIST 1. Turn all knobs to OFF or Normal. 2. Turn on power atthe circuit breaker. 3. Set the clock for current time of day. Refer to the Owner's Manual for instructions. 4. Check oven door for full opening and closing. Oven lights should be on when the door is opened and off when the door is closed.
Notes 15
Note: While performing installations described in this book, safety glasses or goggles should be worn, For Morm_ram _ local service i_ your area, call 1-80(L444_1845. Note: [ roduct inlproxement is a continuing endeaxor at General Electric. Therefore, materials, appearance and specifications m-e sul2ject to change without notice. Monogram: We bring good things to life. Pub. No. 49-80188 Dwg. No. 164D4290P344 1ND.