Installation Instructions 30” Built-In Trivection™ Wall Oven JT930, JT980, ZET3038, ZET3058 Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com BEFORE YOU BEGIN FOR YOUR SAFETY: Read these instructions completely and carefully. ¢ Be sure your oven is installed properly by a qualified installer or service technician. ® IMPORTANT — Save these instructions for local inspector's use. © IMPORTANT — observe all governing codes and ordinances.
Installation Instructions PREPARE TO TOOLS YOU INSTALL THE WILL NEED OVEN PARTS INCLUDED [Pre Ze Drill with 1/8” Bit (Extension may be required) Safety Glasses Metal LQe Bottom Trim ® \ 12 Screws oie Plastic Straight Edge or Bottom Trim Square Adjustable Wrench (for 1-7/16” Nut) —_» OR Pencil er Phillips Screwdriver Metal Bottom Trim Assembly Gloves Hand or Sabre Saw $ MATERIALS YOU MAY NEED Strain Relief Clamp for 1/2” conduit b Junction
Installation Instructions [1] PRE-INSTALLATION [1] PRE-INSTALLATION (CONT.) All installation information on the following pages is to be used for SINGLE and DOUBLE oven installation! NOTE: To prevent damage to the door and to prevent excessive microwave leakage, do NOT remove the door on single wall oven models or the upper oven door on double wall oven models. [A] Remove packaging materials. Check behind hinges.
Installation SINGLE BUILT-IN OVEN Instructions CUTOUT OPTIONS [2] CUTOUT OPTIONS FOR SINGLE BUILT-IN OVENS [A] Skip to Step 3 for Double Built-In Oven models. NOTE: If the cabinet does not have a front frame and the sides are less than 3/4” thick, shim both sides equally to establish the cutout width. There are 4 installation options for single built-in ovens.
Installation WALL MOUNT—SINGLE BUILT-IN OVEN BELOW AN ADVANTIUM OVEN OPTION a Instructions WALL MOUNT—SINGLE BUILT-IN OVEN ABOVE A WARMING DRAWER OPTION Mine , 24" Construct solid bottom min. 3/8” Advantium cutout 23 1/2” Min. — meee inside > Construct solid bottom Pe min. 3/8” plywood / supported by2x4or1 x 2 runners, all four sides plywood Oven cutout 2” Min.
Installation Instructions SINGLE [D] BUILT-IN OVEN UNDER COUNTER—SINGLE CUTOUT OPTIONS (CONT.) BUILT-IN OVEN OPTION 1 3.1/2” Required Junction Box Area Top and/or side fillers may be necessary if unit is positioned between existing cabinets. Be sure they are attached securely, since they will i anchor the oven in the 28 1/2” Min. 28 5/8” Max. --” ~ | 6” Allow 1” overlap 27 1/4” Min. 2 27 5/16" Max.
Installation DOUBLE BUILT-IN OVEN CUTOUT OVEN CUTOUT FOR DOUBLE BUILT-IN CUTOUT FOR DOUBLE BUILT-IN OVEN (CONT.) Cutout Width 28 1/2” Min 7” from side cutout 28 5/8” Max. <——_____» All corners must be cut square 11/16” for M~<« Opening oven over side edges of cutout between inside walls must Allow a be at Least minimum of 21” for clearance ade to adjacent corners, drawers, walls, etc.
Installation Instructions REMOVE THE LOWER OVEN DOOR ON DOUBLE WALL OVEN MODELS ONLY To prevent damage to the door and to prevent excessive microwave exposure, ~~ do NOT remove the door on the single wall oven or the upper oven door on the double wall oven. NOTE: The oven door is heavy. You may need help lifting the door high enough to slide it [4] ON DOUBLE WALL OVEN MODELS, REMOVE THE LOWER DOOR ONLY (CONT.
Installation Instructions ELECTRICAL CONNECTIONS ELECTRICAL REQUIREMENTS ATTENTION This appliance must be supplied with the proper voltage and frequency, and connected to an individual, properly grounded branch circuit, protected by a circuit breaker or fuse having amperage as noted on rating plate. (Rating Plate is located on oven frame.) All electric wall ovens must be hard wired (direct wired) into an approved junction box. A plug and receptacle is NOT permitted on these products.
Installation Instructions ELECTRICAL CONNECTIONS (CONT.) [5] TURN OFF ELECTRICITY Turn off the circuit breaker the oven branch circuit.
Installation Instructions THREE-CONDUCTOR BRANCH CIRCUIT CONNECTION When connecting to a three-conductor branch circuit, if local codes permit: [A] Connect the bare oven ground conductor with the crimped neutral (white) lead to the branch circuit neutral (white or gray in color), using a wire nut. Ground and Neutral Wires Junction Box Cover Connect the oven red lead to the branch circuit red lead in accordance with local codes, using a wire nut.
Installation SECURE THE OVEN Instructions IN THE OPENING [9] SLIDE THE OVEN INTO THE OPENING [A] DRILL THE PILOT HOLES AND MOUNT THE OVEN Loop (do not tie) the correct length of string around the conduit before the oven is slid into place. This will keep the conduit from falling improperly behind the oven.
Installation Instructions To install a single metal bottom trim assembly (on some models), see Step 11. To install a metal bottom trim with a plastic bottom trim (on some models), see Steps 11 and 12. [12] INSTALL THE PLASTIC BOTTOM TRIM (ON SOME MODELS) 6B [11] INSTALL THE METAL BOTTOM TRIM With oven [A] Make sure flat side is up on the plastic installed, take the bottom trim and center it on the bottom front edge of bottom trim. EF the cabinet opening.
Installation Instructions REPLACE THE LOWER OVEN DOOR ON DOUBLE WALL OVEN MODELS ON DOUBLE WALL OVEN MODELS, REPLACE THE LOWER DOOR: [A] Firmly grasp both sides of the door at the top. Bottom edge of slot Indentation With the door at the same angle as the removal position, seat the indentation of the hinge arm into the bottom edge of the hinge slot. The notch in the hinge arm must be fully seated into the bottom of the slot. Fully open the door.
Installation Instructions FINAL CHECKLISTS PRE-TEST CHECKLIST [15] OPERATION CHECKLIST [A] Remove all protective film. [A] Remove all items from the inside of the oven. Check to be sure that all wiring is Check that conduit is securely connected secure and not pinched or in contact with moving parts. to the junction box. Check that the bottom trim is installed Turn on the power to the oven. (Refer properly (see Steps to your Owner’s Manual.