Installation guide
4
31-10755-4
Design Information
PRODUCT DIMENSIONS AND CLEARANCES
48” Range Models
Toekick/
leg Height
3-1/4” 
to 4-3/4”
1-1/2”
35-1/4” 
to 
36-3/4”
Height
47-7/8” 
Width
28-1/4”
13” 
Max.
12” 
Minimum 
Each Side
48” Min.
12” Minimum 
to Adjacent Wall
WARNING:
Installations without a hood require 
48” minimum to combustibles. 
A custom hood installation with 
exposed horizontal combustible 
surfaces must have an Auto-On 
feature. Refer to hood installation 
instructions for specific hood 
clearances.
The surface of the entire back wall 
above the range and below the 
hood must be covered with a non- 
combustible material such as metal, 
ceramic tile, brick, marble or other 
stone.
Non-
Combustible 
Material
48”
8”
11”
21”
Gas/ 
Electric
6-1/2”
2”
3”
Universal Utility Locations
Depth 
to Front 
of Door
Countertop 
to Cooking 
Surface
48” Minimum 
to Combustibles
18” 
Min.
NOTE: All openings in the floor 
or wall behind and below the 
appliance shall be sealed.
ADDITIONAL CLEARANCES:
Allow 12” minimum clearance to an adjacent wall 
on each side.
Working areas adjacent to the rangetop should have 
18” minimum clearance between countertop and 
the bottom of the wall cabinet.
For island installation, maintain 2-1/2 in. minimum from 
cutout to back edge of countertop and 3 in. minimum 
from cutout to side edges of countertop (see top view).
Back
3” Min.
Island
Cutout
Top View
3” Min.
2-1/2” Min.