Advance planning for chimney hoods—wall-mount
Product dimensions and clearances
This vent hood can be installed for vented or recirculating
operation. It can be installed over any 30" or 36" Monogram
cooktop (except Professional models).
ZV800SJSS, Stainless steel
Telescoping duct covers
are provided to reach
8' to 10' ceiling heights.
The canopy extends
forward 5-7/8".
Determine installation height
Use this chart to accurately determine installation height,
depending on your ceiling height.
Wall-mount ZV800 installation heights
Actual ceiling Possible vented Possible recirculating
height installation height* installation
7' 11" 24" to 27" 24" to 25"
8' 0" 24" to 28" 24" to 26"
8' 1" 24" to 30" 24" to 27"
8' 2" 24" to 30" 24" to 28"
8' 3" 24" to 30" 24" to 29"
8' 4" 24" to 30" 24" to 30"
8' 5" 24" to 30" 24" to 30"
8' 6" 24" to 30" 24" to 30"
8' 7" 24" to 30" 24" to 30"
8' 8" 24" to 30" 24" to 30"
8' 9" 24" to 30" 24" to 30"
8' 10" 24" to 30" 24" to 30"
8' 11" 24" to 30" 24" to 30"
9' 0" 24" to 30" 24" to 30"
9' 1" 24" to 30" 24" to 30"
9' 2" 24" to 30" 24" to 30"
9' 3" 24" to 30" 24" to 30"
9' 4" 24" to 30" 24" to 30"
9' 5" 24" to 30" 24" to 30"
9' 6" 24" to 30" 24" to 30"
9' 7" 25" to 30" 24" to 30"
9' 8" 26" to 30" 24" to 30"
9' 9" 27" to 30" 24" to 30"
9' 10" 28" to 30" 24" to 30"
9' 11" 29" to 30" 25" to 30"
10' 0" 30" 26" to 30"
*Based on 36" countertop height.
Venting and recirculating
wall-mount installations
The vent hood must be
installed 24" minimum to
30" maximum above the
standard 36" countertop.
The hood installation height,
from the cooking surface to
the bottom of the hood,
depends on the ceiling height.
Vented or recirculating
installations in a cabinet
The vent hood height must
be at least 24" minimum above
the standard 36" countertop.
• In both vented and
recirculating installations,
the cabinet must measure
at least 20" from the bottom
frame to the inside top.
• The cabinet must be at
least 12" deep. The hood
housing will occupy the
interior cabinet space.
Recirculating installation
• The exhaust must be returned to the kitchen; it cannot exit
inside the cabinet.
• The exhaust can be directed through the soffit or upper
cabinet to a vent opening with a minimum of 28 square
inches or 6" round. A customer-supplied decorative louver
should be installed.
• The exhaust, either exposed or hidden, should be directed
away from other cabinet surfaces.
ZV800SJSS duct cover dimensions
The serial plate is located behind the removable filters.
Charcoal filter replacements are available from your dealer or
by calling 800.626.2002. Order catalog number WB02X11343.
A mounting template is provided with the installation
instructions to help position the hood above the cooking
surface and to locate the mounting brackets.
Louver at top of cabinet
in this example