Installation guide
Installation Instructions
BEFORE YOU BEGIN
Reed these instructions completelg end
carefullg.
, IM PORTANT - savethese instructions for
local inspector's use.
elm PORTANT- Observe all governing codes
and ordinances.
, Note to Installer - Be sure to leave these
instructions with the Consumer.
, Note to Consumer - Keep these instructions for
future reference.
, Skill Level - Installation of this vent hood requires
basic mechanical and electrical skills.
, Completion time- 1to 3 hours.
, Proper installation is the responsibilitg of the
installer.
, Product failure due to improper installation is not
covered under the Warrantg.
For Monogram local service in gour area, call
1.800.444.1845.
For Monogram service in Canada, call
1.800.561.3344.
For Monogram Ports and Accessories, call
1.800.626.2002.
ACAUTION:
Due to the weight and size of these vent hoods
and to reduce the risk of personal injurg or damage
to the product, TWO PEOPLE ARE REQUIRED FOR
PROPER INSTALLATION.
AWARNING:
To reduce the risk of fire or electrical shock, do not
use this range hood with ang external solid-state
speed control device. Ang such alteration from
original factorg wiring could result in damage to the
unit and/or create an electrical safetg hazard.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCTWORK.
A WARNING: TOREDUCETHERISKOF
FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Use this unit onlg in the manner intended bg the
manufacturer. If gou have questions, contact the
manufacturer.
B. Before servicing or cleaning unit, switch
power off at service panel and lock the service
disconnecting means
to prevent power from being switched on
accidentallg. When the service disconnecting
means cannot be locked, securelg fasten a
prominent warning device, such as a tag, to the
service panel.
A CAUTION: ForGeneralVentilating
Use Onlg. Do Not Use To Exhaust Hazardous Or
Explosive Materials And Vapors.
A WARNING: ToREDUCETHERISKOF
FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be
done bg qualified person(s)in accordance with all
applicable codes and standards, including fire-
rated construction.
B. Sufficient air is needed for proper combustion
and exhausting of gases through the flue
(chimneg) of fuel burning equipment to prevent
back drafting. Follow the heating equipment
manufacturer's guideline and safetg standards
such as those published bg the National
Fire Protection Association (NFPA), and the
American Societg for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE),and
the local code authorities. When applicable,
install ang makeup (replacement) air sgstem in
accordance with local building code requirements.
Visit GEAppliances.com for available makeup air
solutions.
C. When cutting or drilling into wall or ceiling, do
not damage electrical wiring and other hidden
utilities.
D. Ducted fans must alwags be vented to the
outdoors.
. Local codes varg. Installation of electrical
connections and grounding must complg with
applicable codes. In the absence of local codes,
the vent should be installed in accordance with
National Electrical Code ANSI/NFPA 70-1990 or
latest edition.