Manual

11
09740-09.2013-DGbFITr
 D 
 GB
 F
 I
 TR
4| Compressor assembly
4.1  Setting up
4.2  Maximum permissible inclination
A
max.30°, 
max.2minutes
a
max.15°,
continuous
operation
ATTENTION! Poor lubrication can damage the compressor. 
  Respect the stated values.
INFO! Newcompressorsarefactory-lledwithinertgas(3barnitrogen). 
  Leave this service charge in the compressor for as long as 
  possible and prevent the ingress of air.
    Check the compressor for transport damage before 
  starting any work.
Fig.8
A
A
a
a
A
A
a
a
 Fittings(e.g.pipeholders,additionalunitsetc.)onthecompressorarepermissibleonly
followingconsultationwithBock.
 Setuponanevensurfaceorframewithsufcientload-bearingcapacity.Thecompressorcan
befastenedasfollows:
 -usingthe4drillholesonthebaseplate
 -usingthe3sideM10tappedblindholesontheleftorrightofthecompressorhousing
 -usingthe4M10tappedblindholesonthefrontofthecompressorhousing.
 Correctsetupofthecompressorandmountingofthebeltdrivearedecisiveforrunning
comfort,operatingsafetyandtheservicelifeofthecompressor.