Manual
 D
 GB
 F
 E
11
96019-02.2015-DGbFEI
Valve spindle seal
Release
Tighten
Fig. 13
Fig. 14
4| Compressor assembly
  Before opening or closing the shut-off valve, release the valve spindle seal by approx. ¼ of a turn 
counter-clockwise.
  After activating the shut-off valve, re-tighten the adjustable valve spindle seal clockwise.
4.6  Operating the shut-off valves
Pipe connection
Pipe connection
4.7 Operatingmodeofthelockableserviceconnections
Fig. 15
Opening the shut-off valve:
Spindle: turn to the left (counter-clockwise) as far as it will go. 
—> Shut-off valve completely opened / service connection closed.
Fig. 16
Opening the service connection
Spindle: Turn ½ - 1 turn to the right clockwise. 
—> Service connection opened / shut-off valve opened.
Service connec-
tion closed
Connection
blocked
Spindle
Service connec-
tion opened
Spindle
Connection
open
Compressor
Compressor
Afteractivatingthespindle,generallytthespindleprotectioncapagainandtightenwith14-16Nm.
This serves as a second sealing feature during operation.