User guide

10
D
GB
F
E
96192-11.2014-DGbFE
4 | Compressor assembly
Setuponanevensurfaceorframewithsufcientload-
bearing capacity.
Provideadequateclearanceformaintenancework.
Ensureadequatecompressorventilation.
Do not use in a dusty, damp atmosphere or a combustible
environment.
INFO! Newcompressorsarefactory-lledwithinertgas(3barnitrogen).
Leave this service charge in the compressor for as long as possible
and prevent the ingress of air.
Check the compressor for transport damage before starting any
work.
Fig. 11
Fig. 12
Fig. 13
4.2 Setting up
?
4.1 Storage and transport
Use transport eyelet.
Do not lift manually!
Use lifting gear!
Storageat(-30°C)-(+70°C),maximumpermissiblerelativehumidity
10% - 95%, no condensation
Do not store in a corrosive, dusty, vaporous atmosphere or in a com-
bustible environment.
Fig. 10
Fig. 9
ATTENTION! Attachments(e.g.pipeholders,additionalunits,fasteningparts,
etc.) directly to the compressor are not permissible!