ATTENTION! Compressor operation is possible within the operating limits
shown in the diagrams. Please note the signicance
of the shaded areas. Thresholds should not be selected as design
or continuous operation points.
- Permissible ambient temperature (-20°C) - (+60°C)
- Max. permissible discharge end temperature 140 °C
-Max.permissibleswitchingfrequency8x/h.
- A minimum running time of 3 min. steady-state condition
(continuous operation) must be achieved.
For operation with additional cooling:
- Use only oils that are highly thermally stable.
- Avoid continuous operation near the limits.
Foroperationwithfrequencyconverter:
- The potential control range of the compressor is 30-70 Hz.
- Max. permissible current consumption must not be exceeded.
Atmax.rotationspeedtherefore,theapplicationlimitcan
be reduced.
- Use a thermal protection thermostat.
- Do not operate an additional capacity controller.
-Oilreturnatlowfrequencymustbeguaranteed.
-ConsultationwithGEABock.
For operation with capacity regulator:
- The suction gas superheat temperature may need to be
reduced or set individuallywhen operating near to the threshold.
When operating in the vacuum range, there is a danger of air
enteringonthesuctionside.Thiscancausechemicalreactions,
a pressure rise in the condenser and an elevated compressed-gas
temperature. Prevent the ingress of air at all costs!
3.3 Limits of application
3| Areas of application
Thecompressorsarelledatthefactorywiththefollowingoiltype:
- for R134a, R404A/R507, R407C FUCHS Reniso Triton SE 55
- for R22 FUCHS Reniso SP 46
Compressorswithesteroilcharge(FUCHSRenisoTritonSE55)aremarkedwithanXinthetype
designation (e.g. HGX22e/190-4A).
3.1 Refrigerants
• HFKW/HFC: R134a, R404A/R507, R407C
• (H)FCKW/(H)CFC: R22
3.2 Oil charge
INFO!
Forrefilling,werecommendtheaboveoiltypes.
Alternatives: seelubricantstable,Chapter7.5.
The oil level must be in the
visible part of the sight
glass; damage to the com-
pressor is possible if over-
filled or underfilled!
ATTENTION!
max.
min.
0,7 Ltr.
oil level
Fig. 4
~
~