Operation Manual

DC 2 – EURO ECO
DC 2 – EURO deluxe
Installation
Manual
The door control DC 2 EURO is designed for hold to run control of power operated doors. The basic version is
designed for hold to run operation only, and you are not allowed to use the automatic function without using
additional safety devices.
Safety Directions
In case of using DC 2 EURO with a permanent mains connection, an all-pole main switch with an appropriate back-up fuse must
be provided.
Before operation, check whether the permissible mains voltage range of the device corresponds to the local mains voltage.
Please note that the door control as well as the motor are for indoor installation only.
During installation, initial operation, maintenance and testing of the DC 2 EURO it is necessary to observe the safety and accident
prevention regulations valid for the specific application. Only trained electrical craftsmen should work on electrical equipment.
Appliance according to the regulations
The door control DC 2 EURO is provided for the operation of sectional-, rollershutter-, folding- and swingdoors.
The manufacturer of the complete installation is responsible. He must take care that the relevant standards and
guidelines (e.g. DIN 1986, EN 12050) have to be respected.
He must take care that a technical documentation of the whole installation is made available.
The technical documentation must be added to the door unit.
Installation, operating and use of the unit against this manual or the described technical specifications causes danger for
persons and produces a liability- and obligations release.
National and regional precautions and standards for the installation, as well as safety precautions of local technical
standards have to be respected.
Technical data
Model DC 2 – EURO deluxe DC 2 – EURO ECO
Supply voltage 230VAC 4,5VA 230VAC 4,5VA
Frequency 50 Hz 50 Hz
Protection class IP 54 IP 54
Outputs motor 3x NO relay contact 230 V / 5 A
2x NO relay contact 230 V / 2 A
1x unregulated supply voltage
24V DC, max. 50mA
3 x NO relay contact 230 V / 5 A
1x unregulated supply voltage
24V DC, max. 50mA
Wiring 1,5 mm² max. 1,5 mm² max.
Operating temperature - 10 C° to + 55 C° - 10 C° to + 55 C°
2