DC MiniMAX 3 R Door control with relais, deadman control, 400V Instruction manual EN conform: EN60335-1 / EN60204-1 in adherence with EN12453 (Safety in use of power operated doors)
Warning Assembly, connection and maintenance of the device may only be executed by personnel trained accordingly. At this the underlying national and local regulations have to be observed. The door control DC MiniMAX 3 R is designed for deadman control of power operated doors. The basic version is designed for deadman operation only, but it can be extended individually by optional modules. Deadman control is only permissible, if the door is in sight of every control device.
Connexion scheme DC MiniMAX R – optical-electronic safety edge X1 PE Supply voltage 230V/50Hz 400V/50Hz L1 L2 D3 L3 X2 M U V Motor 3 x 230V/50Hz Motor 3 x 400V/50Hz W X6 230 400 Selection of supply voltage 1 2 3 X4 J2 J1 J17 Bridged = Automatic run OPEN S02 OPEN ZU S01 CLOSE Auf X8 X7 Bridged = Automatic run CLOSE J21 OPEN CLOSE Limit switch OPEN Limit switch CLOSE brown braun green grün white weiß Optical-electronic safety edge * X3 J5 STOP X6 1 2 3 4 Pre- limit switch Imp
Connexion scheme DC MiniMAX R – 8,2 kOhm resistor logic X1 PE Supply voltage 230V/50Hz 400V/50Hz L1 L2 D3 L3 X2 M U V Motor 3 x 230V/50Hz Motor 3 x 400V/50Hz W X6 230 400 Selection of supply voltage 1 2 3 X4 J2 J1 J17 Bridged = Automatic run OPEN S02 OPEN ZU S01 CLOSE Auf X8 X7 Bridged = Automatic run CLOSE J21 X3 J5 STOP X6 1 2 3 4 Pre- limit switch Impulse input Safety devices J5, J17 and J21 have to be bridged, if the terminals X6, X7 and X8 are not in use! 24V DC 250mA +
Technical data Supply voltage 230 V or 400 V Frequency 50 Hz Protection class IP 54 A max.