Operation Manual

Safety advice
Assembly, connection and maintenance of the device may only be executed by personnel trained
accordingly. Use for the installation of the Rollotimer a deep switch box. Please pay attention that no
cables are affecting the proper latching of the device. To prevent overvoltage and therewith a
malfunction, plug or unplug the operation panel only in de-energized state! For this purpose
disconnect the power supply of the electric circuit by switching off the corresponding fuse.
Technical Data Ref. No. 941.DCZ2.00
Power supply 230V / 50Hz
Switching voltage 250 V AC
Switching contact load 3 A (cos phi=1)
Ambient temperature +5°C to +45°C
Running time 2,5 minutes (max.)
Changeover delay min. 0,5 seconds
Accuracy < 5 seconds /day
Power reserve approx. 0,5 minutes
Protection class IP 20
Safety class II
Conformity CE
Installation and
operation manual
ROLLOTIMER Standard
Ref. No. 941.DCZ2.00
M
PE green/yellow
N blue
L black/brown
blue
brown or black
blue
brown or black
brown or black
Connection diagram
N L N ZU AUF
N NL
down up
X0469

Summary of content (2 pages)