997.006.00.
Product Data 393/8" (1000) 43/4" (120) 173/8" (440) NPT 1/2" 13/8" (33.5) 3/4 - 31/2" (20 - 90) 91/4" (235) 331/4" (845) 20" (510) 411/8" (1045) 143/8" (365) 421/2" (1080) 9" (230) 22" (558) FRH 53/8" (135) FF Product Specifications Concealed tank for wall-hung two-hole toilet bowl and actuator plate. Water supply shall be 1/2" copper, minimum water pressure 35 PSI. The bowl shall be an IAMPO listed 1.6 gallon (6 l) per flush wall-hung bowl.
Warranty Limited lifetime warranty on tank. 10 year warranty on fill valve and flush valve. One year warranty on actuator plate. Tank Installation Standards In compliance with - ASME 112.19.6 - ASME 112.6.2 - ASSE 1002 - CSA B125-98 Installation Installation Requirements To install the tank a 2 x 6" wood frame construction is required. Studs must be placed 21 1/2" apart (clearance) where carrier will be positioned inside the wall.
1 3 1 3 2 1 79 80 81 82 83 84 85 86 87 88 89 90 91 92 61/8" (155) 1/2" ~ 21 ) (550 2 4 53-65 2 4 5 Mark location for the 3" DWV discharge pipe. With unit still in place, establish location for the water supply NPT elbow for rear inlet connection.
Bowl Installation 6 1 1 Remove yellow protection plugs and seals from pipes. 2 Insert discharge pipe into the pipe hub in the wall. Place a straight edge flush against the wall and mark a line on the pipe. Fit finned rubber seal onto flush pipe. Repeat same procedure for discharge pipe. 2 2 3 2 2 2 D31811-001&BDC © 07-2008 3 7 Install 3" DWV waste pipe through floor and connect to waste line (i.e. PVC, copper, cast iron).
4 Add dimension X and 1/8". Using that dimension, mark a line on the pipe measuring from the hub side. Cut off the pipe at the line with a pipe cutter. 7 Install both seals into the pipes in the wall. Lubricate seals with appropriate rubber seal lubricant. 8 Remove protective sleeves from mounting rods. Determine protruding rod length for bowl installation. Install both pipes into the hubs in the wall. X 2 5 1 +1/8" +(3 mm) X Add dimension Y and 1/8".
10 Sound insulation pad is optional or required. Seal gap around bowl with waterproof sealant.
Service Troubleshooting PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION WATER CONTINUES TO RUN AFTER FLUSH CYCLE IS COMPLETED Flush valve is not seated properly. Remove actuator plate or access panel to reach flush valve. Press valve down to ensure complete seal. Water runs into overflow tube; the water level is too high in tank. Remove actuator or access panel. Turn spindle counterclockwise to lower water level in tank. Water is leaking from fill valve. Remove actuator or access panel. Check connection.