EDID MODES
EDID Modes
The diagram below illustrates the 4-position DIP switch bank (containing 4 small
white toggle switches as shown). The functions of the switches are as follows:
DIP SWITCH Function
1 IR Channel
2 IR Channel
3 EDID Mode
4 N/A
Use DIP switch 3 to set the desired EDID mode. (UP is On)
How to set the two EDID Modes:
1. LOCAL EDID Mode ON (Switch 3 = OFF, FACTORY DEFAULT SETTING)
• During power-on, the connected display’s EDID is copied to all four
LOCAL EDID storage locations at once. EDID stored in LOCAL memory
is then passed to all input sources.
• The EDID stored in the LOCAL locations can be overwritten with another
EDID from the following locations:
• Built-in EDID memory bank (up to 7 EDID records can be stored)
• EDID collected directly from the input display upon power-up*
Note: All changes to EDID in Local EDID Mode will be lost upon power loss.
2. Local EDID Mode OFF (Switch 3 = ON)
• The DDC signal of the connected display is routed directly to each input
source. Each time a new source device is selected, EDID is transmitted
from the attached display to the currently selected input source. (This
mode will successfully pass HDCP signals.)
*For EDID writing to be successful the Switcher must be powered on.