#set_horz_scan_rate
Sets the horizontal scan rate and saves it to the specied preset. param1 is a oating-point
value and can be specied up to three decimal places.
Syntax
#set_horz_scan_rate param1 param2
Parameters
param1 Scan rate (kHz) [0.000 ... 999.000]
param2 Preset [0 ... 5]
Example
#set_horz_scan_rate 45 1
HORIZONTAL SCAN RATE 45 SAVED TO PRESET 2
Related Commands
#get_timing_preset
#set_horz_active
#set_horz_back_porch
#set_horz_front_porch
#set_horz_sync_polarity
#set_horz_sync_width
#set_horz_total
#set_pixel_clock
#set_vert_active
#set_vert_back_porch
#set_vert_front_porch
#set_vert_refresh_rate
#set_vert_sync_polarity
#set_vert_sync_width
#set_vert_total