RS-232 / IP CONTROL
38
#resetip Command
The#resetipcommandresetsallTCP/IPsettingstofactorydefaults.
Syntax:
#resetip
Parameters:
None
Notes:
Thematrixmustberebootedafterexecutingthiscommand.
Example:
#resetip
IP Conguration Was Reset To Factory Defaults.
Afterrebootingthematrix,theIPsettingswillbecleared.Runningthe#ipcong
commandwilldisplaytheupdatedinformation:
#ipcong
IP: 192.168.1.120
NETMASK: 255.255.255.0
GATEWAY: 192.168.1.254