2.1 Application Interface
52
ELS61-AUS_HID_v00.031 2016-06-03
Confidential / Preliminary
Page 22 of 102
2.1.2.1 Absolute Maximum Ratings
The absolute maximum ratings stated in Table 3 are stress ratings under any conditions.
Stresses beyond any of these limits will cause permanent damage to ELS61-AUS.
Table 3: Absolute maximum ratings
Parameter Min Max Unit
Supply voltage
BATT+
BB
, BATT+
RF
-0.5 +5.5 V
Voltage at all digital lines in Power Down mode -0.3 +0.3 V
Voltage at digital lines in normal operation -0.2 V180 + 0.2 V
Voltage at SIM/USIM interface, CCVCC in normal operation -0.5 +3.3 V
VDDLP input voltage -0.15 2.0 V
Voltage at ADC line in normal operation 0 1.2 V
Voltage at analog lines in Power Down mode -0.3 +0.3 V
V180 in normal operation +1.7 +1.9 V
Current at V180 in normal operation -50 mA
VCORE in normal operation +0.85 +1.25 V
Current at VCORE in normal operation -50 mA