24
Immunity test IEC60601-1-2 test Compliance level Electromagnetic environment — guidance
Power frequency
(50/60 Hz)
magnetic field
IEC 61000-4-8
3 A/m 30 A/m Power frequency magnetic fields should be at levels
characteristic of a typical location in a typical commercial
or hospital environment.
Conducted RF
IEC 61000-4-6
6 Vrms
150 kHz to 80 MHz
6 Vrms
150 kHz to 80 MHz
Portable and mobile RF communications equipment should
be used no closer to any part of the device, including
cables, than the recommended separation distance
calculated from the equation applicable to the frequency
of the transmitter.
Radiated RF
IEC 61000-4-3
9 V/m to 28 V/m at
frequencies up to 5.785
GHz
27 V/m to 85 V/m at
frequencies up to 5.785
GHz
The device complies with all applicable electromagnetic
compatibility requirements (EMC) according to IEC60601-
1-2:2014, for residential, commercial and light industry
environments. Portable and mobile RF communications
equipment should be used no closer to any part of the
device including cables, than the recommended 3.9" (10
cm) separation distance.
The device has been designed to meet EMC standards.
However, should you suspect that the device performance
(eg pressure or flow) is affected by other equipment, move
the device away from the possible cause of interference.
Operation is subject to the following two conditions: This
device may not cause harmful interference, and this
device must accept any interference received including
interference that may cause undesired operation.
Notes:
• Ut is the AC mains voltage prior to application of the test level.
• At 80 MHz and 800 MHz, the higher frequency range applies.
• These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection
from structures, objects and people.
Symbols
Follow instructions before use. Temperature limitation. Humidity limitation. Operating
altitude. Atmospheric pressure limitation. Manufacturer. Direct current. On / Off.
Class II equipment. Protected against finger sized objects and against dripping water when tilted
up to 15 degrees from specified orientation. Non-ionising radiation. MR unsafe (do not use in the
vicinity of an MRI device). RTCA/DO-160 Section 21, Category M Compliant & FAA Compliant. Type
BF applied part. Date of Manufacture Medical device. Catalog number. Device
number. Serial number. Batch code. European Authorized Representative.
See symbols glossary at ResMed.com/symbols.
Environmental information
This device should be disposed of separately, not as unsorted municipal waste. To dispose of your device,
you should use appropriate collection, reuse and recycling systems available in your region. The use of
these collection, reuse and recycling systems is designed to reduce pressure on natural resources and
prevent hazardous substances from damaging the environment.
If you need information on these disposal systems, please contact your local waste administration. The
crossed-bin symbol invites you to use these disposal systems. If you require information on collection and
disposal of your ResMed device please contact your ResMed office, local distributor or go to
ResMed.com/environment.