USER MANUAL HANDBUCH HANDLEIDING MANUEL DESCRIPTIF РУКОВОДСТВО ПОЛЬЗОВАТЕЛЯ КЕРІВНИЦТВО КОРИСТУВАЧА
SIS-PWM Silver Shield(TM) advanced surge protector with power meter Silver Shield(TM) advanced surge protector with power meter Silver Shield (TM) Advanced Surge Protector mit Leistungsmesser Silver Shield(TM) geavanceerde surge protector met stroom meter Silver Shield (TM) de pointe de surtension avec mesureur de puissance Silver Shield (TM) Сетевой фильтр с функцией измерения потребляемой мощности Silver Shield (TM) Мережевий фільтр з функцією вимірювання споживаної потужності 2 All brands and logos ar
SIS-PWM Silver Shield(TM) advanced surge protector with power meter Features • USB interface power meter provides readings of voltage, current, power and energy consumption • Supplied with the software calculating the energy costs • Power meter function does not require permanent connection to the computer • 6 socket AC power surge protector 230 VAC, 10A • Protection from surges, spikes, radio-frequency noise (EMI/RFI filter) • Built-in circuit breaker and overload protection Specifications • Power rating
SIS-PWM Silver Shield(TM) advanced surge protector with power meter • Computer measurements: voltage and current measuring (RMS, peak values), power measuring (true, apparent, reactive), real and full energy consumed during a time period (kWH) • Measurements range: up to 250 VAC, 10 A (RMS), 2500 W, 22.000 kW a year • Working conditions: +10...
SIS-PWM Silver Shield(TM) advanced surge protector with power meter 2.
SIS-PWM Silver Shield(TM) advanced surge protector with power meter 2.
SIS-PWM Silver Shield(TM) advanced surge protector with power meter 4. Hardware requirements • Windows XP/2003/Vista/Windows 7 • USB port 5. Package contents • • • • SIS-PWM User manual USB cable CD with SIS-PWM Power Meter software for Windows 6. Installation of SIS-PWM To use SIS-PWM please follow next steps: 1. Install the software. 2. Connect the SIS-PWM to the PC with USB cable.
SIS-PWM Silver Shield(TM) advanced surge protector with power meter • It is possible to connect the SIS-PWM to the power source via other multi-plugs, surge protectors, voltage regulators or UPS. 7. Software installation a. Insert CD with the software into the PC CD-ROM drive. b. If for any reason the automatic setup does not work, then open CD-ROM drive in the “My computer” window and launch SETUP.EXE from the CD. Follow instructions of the installation software. 8.
SIS-PWM Silver Shield(TM) advanced surge protector with power meter 9. Operating the SIS-PWM SIS-PWM has 2 modes of working: on-line mode, when it is connected to Power Meter software, and off-line mode, when it is disconnected from computer or Power Meter software is not run. In online mode, all the power characteristics are calculated and displayed in Power Meter software window, and energy consumed is being counted.
SIS-PWM Silver Shield(TM) advanced surge protector with power meter voltage limits. It warns about dangerous conditions of power mains, which may cause damage to some equipment. Indicator ‘L” (means Load) lights or blinks, if the equipment has inductive or capacitive type of the load. Such equipment may cause EMI noise and voltage spikes to the power mains. On most such kinds of loads it blinks in the moment of it’s powering on or off.
SIS-PWM Silver Shield(TM) advanced surge protector with power meter Figure 2 – Main display window The energy rate settings are set in a window, which is popped up upon pressing “Set” button near the “Cost” indicator. Choose cost rate (per kWh), currency type and press “OK” for applying the changes. If rate differs in day and night, check “Use Day/Night modes” and input rates, day and night start times.
SIS-PWM Silver Shield(TM) advanced surge protector with power meter For setting voltage warning limits – press “Set” button nearby and input it in newly opened window. Figure 3 – Energy rate settings window While running Power Meter software logs measured power consumption to MS Access database file log.mdb located in the application directory. One can view logged data in the form of a chart by selecting “Show chart” tray menu item. There are two display options In the chart window (Figure 4.
SIS-PWM Silver Shield(TM) advanced surge protector with power meter periods of time when software was quit are shown as grayed out areas in the chart. By clicking “Export” button one can export data from database file to MS Excel file. Use “Clear & Close” button to purge logged data.
SIS-PWM Silver Shield(TM) advanced surge protector with power meter 11.
SIS-PWM Silver Shield(TM) advanced surge protector with power meter 12. Troubleshooting Problem The circuit breaker is activated. (Tripped) Indicator “Self-test” is off Software reports "Device I/O request error". Solution The load connected to the unit is too high, some of the devices connected to the SIS-PWM should be disconnected and the circuit breaker should be reset.
SIS-PWM Silver Shield(TM) advanced surge protector with power meter 16 All brands and logos are registered trademarks of their respective owners
SIS-PWM Silver Shield(TM) advanced surge protector with power meter 17 All brands and logos are registered trademarks of their respective owners
SIS-PWM Silver Shield(TM) advanced surge protector with power meter WARRANTY CONDITIONS The warranty period is 36 months and begins with the sale to the end user. The receipt must clearly list the date of purchase and the part number, in addition it should be printed. Keep the receipt for the entire warranty period since it is required for all warranty claims. During the warranty period the defective items will be credited, repaired or replaced at the manufacturer's expense.
SIS-PWM Silver Shield(TM) advanced surge protector with power meter GARANTIE VOORWAARDEN CONDITIONS DE GARANTIE De garantietermijn bedraagt 36 maanden en gaat in op de aankoopdatum van het product door de eindgebruiker. Op de aankoopbon moeten de aankoopdatum en productomschrijving duidelijk vermeld staan. Gelieve de aankoopbon de gehele garantieperiode te bewaren, deze is ten alle tijden benodigd voor alle garantie aanspraken.
SIS-PWM Silver Shield(TM) advanced surge protector with power meter ГАРАНТИЙНЫЙ ТАЛОН 1. Гарантийное обслуживание предоставляется в течение срока гарантии, при наличии правильно и четко заполненного гарантийного талона, и изделия в полной комплектации. Серийный номер и модель изделия должны соответствовать указанным в гарантийном талоне. 2. Гарантийное обслуживание представляет собой бесплатное устранение всех неполадок (ремонт), или замену изделия на новое (аналогичное). 3.