Clear Modem Series G User Guide Model: WIXB-175 Manual Version: 1.3 Manual Date: July.
Overview Thank you for purchasing the Clearwire CPE Indoor (WIXB-175) desktop device. The Desktop CPE allows you to connect to the wireless world easily and seamlessly without complicated installation and setup procedures. In addition it offers you the ability to make Voice over Internet Protocol (VoIP) calls. The Desktop CPE indoor device provides the user: Convenience — with easy plug and play functionality. Performance — High gain antennas supply diversity technology.
Power Status The Power LED shall be on when the device is plugged in and has power. Ethernet Status The Ethernet LED should be on when the LAN Ethernet has been established and activity has been detected. Signal Strength Once the device has registered on the network, the Signal Strength LEDs should be on depending on different strength. Only one Signal Strength LED lit represents low signal detected and all five Signal Strength LED lit presents high signal detected.
Ethernet Cable The Ethernet cable connects the Internet port on your Clear Modem to your PC or laptop computer. Clear Modem Quick Start Guide Provides quick installation instructions for getting your Desktop CPE up and running. Welcome Letter A brief introduction of the stuff inside the packaging and customer service contact window.
Procedure to Log into the CPE Before you Begin Configuration, some settings on your computer must be verified or changed to ensure that your computer configuration can support the Desktop CPE. Verify that the IP addresses and DNS settings are automatically generated in your Local Area connection of your Internet Protocol (TCP/IP) properties. Refer to the chapter titled "Configuring TCP/IP" for information on how to do this. Logging In to the CPE Use the following procedure to log into the Desktop CPE. 1.
Basic Menu The Basic menu provides the following tabs: Password Time Zone Device Name Reset Factory Settings Password Tab The password tab allows you to enable/disable password protection. You can also change your password here. Field or Button Description Enable Login Password Checking this box will require login password Protection protection. New Login Password Enter your new password here. Maximum 20 characters. Passwords are case-sensitive.
Time Zone Tab The Device Time Zone tab allows you to establish the time zone for your location. It also allows you to automatically adjust for Daylight Savings Time if necessary. Field or Button Description Current Local Time Shows the current local date and time. Time Zone Select your local time zone from the drop down box. Auto Adjust for Daylight Check this box if your location observes Daylight Saving Time Savings Time.
Device Name Tab The Device Name tab allows you to re-name your CPE device. This is the Device Name you enter on an internet browser address bar to access your CPE device. Field or Button Description New Device Enter the new name for the CPE device. Name Maximum 20 characters. Be sure to click the Apply button once you are finished.
Restore Factory Settings Tab The Restore Factory Settings Tab will reset your CPE to the manufacturers default settings. Be sure to click the GO button if you are sure you want to reset factory settings. The CPE will reboot automatically after the GO button has been clicked.
Firewall Tab A firewall helps to protect your home network from unauthorized access. It will also help to manage authorized access from the internet to your CPE Field or Button Description Enable Firewall Check this box to enable the firewall for your home network. Enable Web Login from Internet (Grayed out if Enable Firewall is not selected). Check this box to enables you to access your CPE device from a network other than your own.
Internet Protocol Tab Please check with your service provider for these settings. If you are unsure of the settings, leave the default values set and click the Apply button If your service provider has instructed you to change any of these settings, be sure to click the Apply button when you are finished.
their domain name associated with an ever changing IP address. As an example, DDNS is used when you are hosting your own website Field or Button Description Enable DDNS Check this box to Enable DDNS (default is unchecked). DDNS Service Provider DDNS User Name DDNS Password Select DDNS Service Provider that you belong to from the drop down box. Only valid if Enable DDNS is checked. Enter your DDNS account user name. Only valid if Enable DDNS is checked. Enter your DDNS account password.
Field or Button Description Enable UPnP IGD Enables Universal Plug and Play (UPnP) Internet Gateway Device (IGD) profile to allow certain Windows applications to setup the port forwarding rule dynamically when NAT is enabled on this device. DMZ (DeMilitarized Zone) Enter the DMZ IP Address. IP Address Be sure to click the Apply button once you have made changes.
Forwarding Tab Click on the ADD button to create additional Port Fowarding rules Field or Button Description Select Select a box when you want to delete the specific row. Protocol Select TCP (Transmission Control Protocol) or UDP (User Datagram Protocol). WAN Port Start Enter the beginning port range for external network access. WAN Port End Enter the ending port range for external network access. LAN IP Address Enter the IP address to host the service.
DHCP Server Lease Status Lease Reservation DHCP Server Tab The DHCP Server tab enables Dynamic Host Configuration Protocol (DHCP) server functionality on the LAN, allowing the router to dynamically assign lease IP addresses to clients that connect to it from the local network. Field or Button Description Enable DHCP Server If selected, the DHCP server on the gateway assigns IP addresses to the computers and other hosts on your network if they have DHCP enabled.
be 192.168.15.2 (or higher). DHCP Ending IP Sets the final IP address assigned by the DHCP Address server. If the DHCP server runs out of DHCP addresses, users cannot access network resources. If this happens, increase the Ending IP or reduce the Lease Time. DHCP Lease Time Sets the time, in seconds, that a network computer remains connected to the gateway using its current assigned IP address. At the end of this time, the DHCP server renews the lease or assigns the computer a new IP address.
Field or Button Description Client Host Name Displays the client host name. The Name field is limited to 20 characters (only 5 appear in display). MAC Address Media Access Control (MAC) address. IP Address Shows the IP Address for each active lease. Remaining Lease Duration Shows the amount of time, in seconds, remaining in the lease. Be sure to click the Apply button once you have made changes.
deleted. Client Host Name Enter the client host name. The Name field is limited to 20 characters (only 5 appear in display) MAC Address Media Access Control (MAC) address. Enter the MAC address of the device. IP Address Enter the IP address that you want assigned to the MAC Address. Enabled Checking this box enables the lease reservation. Be sure to click the Apply button once you have made changes.
Why does my WiMAX signal vary? Interference due to materials between the cell tower and the modem, including buildings and trees, could cause the signal to be weak in specific areas, even within the coverage area. How do I receive the strongest signal possible? Use the signal strength LEDs on the modem to find the room or location with the strongest signal. Additional Troubleshooting Help Contact your service provider for additional help via Clear Care at 888-888-3113.
Regulatory Notices Model No: WIXB-175 WiMAX CPE Operating Frequency Range: 2.5GHz~2.7GHz Bandwidth: 5MHz/10MHz Operation temperature: 0℃~40℃ Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
transmitter. The availability of some specific channels and/or operational frequency bands are country dependent and are firmware programmed at the factory to match the intended destination. The firmware setting is not accessible by the end user.