About Gemtek Small Cell Grounding Construction
(1)The position of the grounding rod and the Gemtek Small Cell must be the shortest position of the
grounding wire.
(2)The grounding rod needs at least 8 inches from the ground.
(3)Connect the grounding clip to the grounding rod. You will use this grounding clip to provide a grounding
band connection between the Small Cell and the outdoor antenna, refer to the ground connection
diagram.
(4)Connect the grounding band to the grounding wire.
(5)Remove the ground screw of Gemtek Small Cell. Position the ground screw through the grounding band
and reinstall the Gemtek Small Cell.
(6)Connect the grounding band to the grounding clamp and refer to the ground connection diagram.
(7) Gemtek Small Cell grounding construction is completed.
<Gemtek Small Cell Grounding Point Diagram>
<Ground Connection Diagram>