7300 Series Operating Manual Genelec 7360A and 7370A Smart Active Subwoofers 750-7360A/7370A
Genelec 7360A and 7370A Smart Active Subwoofers Introduction Congratulations and a thank-you for the purchase of this Genelec 7300 series subwoofer. This manual addresses setting up and using the Genelec 7360A and 7370A subwoofers. These subwoofers are designed to integrate easily into all environments, both those using analog audio as well as those using digital AES/EBU audio.
BYPASS SWITCH CONNECTOR 7360A SMART ACTIVE SUBWOOFER AVERTISSEMENT WARNING CONTROL SWITCHES BASS ROLL-OFF PHASE DIGITAL LFE LFE CHANNEL LFE +10 dB LEVEL THIS DEVICE COMPLIES WITH FCC PART 15 AND CANADIAN ICES-003 RADIO FREQUENCY CLASS B EMISSION REQUIREMENTS. REFER TO OPERATING MANUAL FOR FULL INFORMATION. -4 dB -8 dB -90° -180° ON/OFF A/B -10 dB -20 dB TEST TONE ISS STORED INPUT dBu PRODUCING 100 dB SPL (1 m) ON OFF 0 -2 -4 www.genelec.com Figure 1. Connector panel of the 7360A.
connector. When using the LFE signal, also run a cable from the LFE Out to the next subwoofer’s LFE In. Control Switches BASS ROLL-OFF controls compensate for the very low frequency boost, reducing the 20 Hz level in 4 dB steps. The settings add to a total of 12 dB attenuation. Setting both switches to "OFF" obtains a flat response. Phase Difference: 90° Phase Difference: 0° 85 Hz PHASE switches can put the subwoofer in phase with a selected main monitor.
should be set to “OFF”. The “LFE +10 dB” function should not be used in the following cases: • If the +10 dB LFE gain is already implemented by another device, for example, a surround sound processor or the output matrix of a mixing console. • When producing an audio format that does not require the use of +10 dB gain on the LFE channel.
Level vs Freq (Hz) Bass Roll-Off -4, -8 and -12 dB 7360A 25.4.16 +100 Bass Roll-Off -4, -8 and -12 dB LFE channel +80 7370A 25.4.16 LFE channel +80 Main channels Main channels +60 +60 +40 +40 +20 +20 +0 10 Level vs Freq (Hz) dB SPL Modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment under FCC rules. +100 dB SPL • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
SPECIFICATIONS Model 7360A 7370A Lower cut-off frequency -6 dB 19 Hz 19 Hz Upper cut-off frequency -6 dB (main channel/LFE) 100 Hz/150 Hz 100 Hz/150 Hz Accuracy of frequency response +/-3 dB 19 Hz - 100 Hz 19 Hz - 100 Hz Driver 250 mm (10 in) (magnetically shielded) 305 mm (12 in) (no magnetical shielding) Harmonic distortion at 1 m on axis in half space, 30 to 85 Hz 2nd ≤ 3% @ 90 dB SPL 3rd ≤ 2% @ 90 dB SPL 2nd ≤ 3% @ 95 dB SPL 3rd ≤ 3% @ 95 dB SPL Maximum short term sine wave SPL output
7360A and 7370A Operating Manual www.genelec.com Genelec Document D0134R001 Copyright Genelec Oy 5.2016. All data subject to change without prior notice International enquiries: In the U.S. please contact: In China please contact: In Sweden please contact Genelec, Olvitie 5 Genelec, Inc.