User's Manual

Figure 1. Connector panel
of the 7360A. The 7370A
is similar.
Figure 2. GLM Network cabling. Audio cabling not shown.
MICROPHONE
PLACED IN
THE LISTENING
POSITION
292-0063
GLM
TERMINATOR
COMPUTER
RUNNING
GLMSOFTWARE
USB CABLE
GLM ADAPTER
GLM NETWORK
CABLE
MONITORS
SUBWOOFER
Y-cables from the source to the
subwoofer's IN connector and the
monitor's signal input.
Signal sources with dual outputs for each
channel.
Use With GLM™
Control Network
Subwoofers are fully compatible with
Genelec Loudspeaker Manager GLM™ and
the proprietary Genelec monitor control
network and Genelec SAM monitors. Using
the GLM control method unleashes the full
room compensation power in the subwoofer,
with 20 parametric room compensation
lters. This level of room compensation detail
is only available when the GLM is used. Use
with the GLM™ network is described in the
GLM System Operating Manual.
System setup
Although the subwoofer can be used without
the GLM™ software and control network,
they only reach their full potential when
set up and calibrated using the GLM™
software. Genelec Loudspeaker Manager
GLM™ and the proprietary Genelec
monitor control network offer automated
acoustic equalization and alignment for any
reproduction system from simple stereo to
very complex 3D immersive setups including
also one or more subwoofers. GLM setup is
fast and accurate and can precisely address
the typical narrow-band low frequency mode
resonances of a room, or typical radiation
load frequency response compensation. The
settings can be controlled with a computer
or be permanently stored in the monitors to
make the setup available at all times even
when a computer is not in use. Genelec
recommends setting up SAM monitoring
systems using GLM. You can nd a detailed
description of the setup and the use of
GLM™ in the GLM™ System Operating
Manual.
The setup is fast and consists of the
following steps:
Connect a CAT5 (RJ45) cable between
each monitor (and subwoofer) and nally
to the control network input of the GLM
Adapter device (see Figure 1).
Connect the GLM Adapter device to
computer USB connector.
Using a microphone stand, place the
Genelec measurement microphone at the
listening location with the microphone
IN 3IN4
OUT 3 OUT 4
IN 5
OUT 5
IN 6IN7
OUT 6 OUT 7
LFE IN
LFE OUT
LINK OUT
LINK IN
OUT 2
IN 1IN2
OUT 1
TEST 1
TEST 2
GLM NETWORK
ANALOGANALOGANALOG
SERIAL
NUMBER
RESET TO FACTORY
SETTINGS: PUSH
BUTTON FOR 10 SEC
MAINS INPUT
50 /60Hz300 W
100-240 V~
-4
0
+2
-2
-6
+4 +12
+8
PHASE
LFE +10 dB
STORED
ISS
TEST TONE
A/B
DIGITALLFE
-20dB
-10dB
LEVEL
BASS ROLL-OFF
BYPASS
ON/OFF
LFE CHANNEL
7360A SMART ACTIVE SUBWOOFER
WARNING
ELECTRIC SHOCK HAZARD. DO
NOT OPEN. DO NOT SUBJECT
TO WATER OR MOISTURE. NO
USER SERVICEABLE PART S
INSIDE. REFER SERVICING TO
QUALIFIED PERSONNEL. USE
EARTHED MAINS CONNECTION
ONLY.
THIS DEVICE COMPLIES
WITH FCCPART15AND
CANADIAN ICES-003 RADIO
FREQUENCY CLASSBEMISSION
REQUIREMENTS. REFER TO
OPERATING MANUAL FOR FULL
INFORMATION.
LAITE ON LIITETTÄVÄ SUOJAKOSKETTIMILLA
VARUSTETTUUN PISTORASIAAN.
APPARATETMÅ TILKOPLES JORDET STIKKONTAKT.
APPARATENSKALL ANSLUTAS TILL JORDAT UTTAG.
RISQUEDE CHOC ÉLECTRIQUE. NE PAS OUVRIR. NE PA S
EXPOSERÀL'EAU OU L'HUMIDITÉ. AUCUN COMPOSAN
L'INTÉRIEUR REMPLAÇABLE PA RL'UTILISATEUR. ADRESSER
TOUTE RÉPARATIONÀUN PERSONNEL QUALIFIÉ.
CET APPAREILDOIT ÊTRE RACCORDÉÀLATERRE.
AVERTISSEMENT
MADE IN FINLAND
www.genelec.com
ON OFF
-90°
-180°
-4 dB
-8 dB
INPUT dBu
100 dB SPL (1 m)
PRODUCING
DIGITAL
OUT
IN
AES/EBU IN/OUT
CONNECTORS
GLM NETWORK
CONNECTORS
ANALOG
IN/OUT
CONNECTORS
POWER
SWITCH
MAINS
INPUT
ROTARY
LEVEL
ADJUSTMENT
CONTROL
SWITCHES
BYPASS
SWITCH
CONNECTOR