User's Manual
SPECIFICATIONS
Model 7380A
Lower cut-o frequency -6 dB 16 Hz
Upper cut-o frequency -6 dB (main channel/LFE) 100 Hz/120 Hz
Driver 381 mm (15 in)
Harmonic distortion at 1 m on axis in half space, 30 to 85 Hz
2nd
3rd
≤ 1% @ 100 dB SPL
≤ 2% @ 100 dB SPL
Maximum short term sine wave SPL output averaged from 30 to 85 Hz,
measured in half space at 1 meter
≥ 119 dB SPL
Maximum peak SPL output with random pink noise, measured in half
space at 1 meter
≥ 123 dB SPL
Self generated noise at 1 m on axis (A-weighted) <5 dBA
Weight 69 kg (152 lbs)
Dimensions H x W x D 685 x 718 x 492 mm (27 x 28
1
/4 x 19
3
/8 in)
SIGNAL PROCESSING SECTION
Signal connectors 7.1 channel analog IN/OUT
Analog Link IN/OUT
Digital AES/EBU IN/OUT
Analog signal input connector XLR female, balanced 10 kOhm
Maximum analog input signal
Analog input sensitivity (100 dB SPL at 1 m)
A
djustment range (LEVEL dip switches + rotary level control)
pin 1 gnd, pin 2 non-inverting, pin 3 inverting
+24.0 dBu
-6 dBu
+48 dBu to -6 dBu
Digital signal input connector XLR female 110 Ohm
Digital signal output / Thru connector XLR male 110 Ohm
Digital audio input
Word length
Sample rate
Digital input sensitivity (100 dB SPL at 1 m)
Digital input maximum attenuation
Positive input gain selection (GLM control)
AES/EBU Single Wire
AES/EBU Single Wire
16 - 24 bits
32 - 192 kHz
-30 dBFS
48 dB
+6, +12, +18 dB
Control network
Type
Connection
Proprietary GLM network
2 RJ45, CAT5 cables
GLM
TM
software frequency response adjustment parametric notch lters 20
System calibration Genelec GLM AutoCal™, GLM manual, Stand-alone
Crossover setting in subwoofer's input/output channels
Centralized Bass Management (for analog signal)
Distributed Bass Management (GLM control)
Input low pass xed 85 Hz, output high pass xed 85 Hz
Input low pass selectable 50 to 100 Hz, output no ltering
LFE cuto 120 Hz
Midband rejection >400 Hz ≥ 50 dB
Bass Roll-O control operating range in 4 dB steps 0 to -12 dB at 20 Hz
Phase matching control 90° steps with dip switch controls
15° steps with GLM control
AMPLIFIER SECTION
Short term amplier output power
(Long term output power is limited by driver unit protection circuitry)
800 W
Amplier system THD at nominal output <0.01%
Mains voltage 100-240 VAC 50/60 Hz
Power consumption
Standby, ISS active
Idle
Full output, peak
<2 W
40 W
600 W