Manual
7380A Operating Manual
Genelec Document D0148R001. Copyright Genelec Oy 5.2017. All data subject to change without prior notice
www.genelec.com
International enquiries:
Genelec, Olvitie 5
FIN-74100, Iisalmi, Finland
Phone +358 17 83881
Fax +358 17 812 267
Email genelec@genelec.com
In the U.S. please contact:
Genelec, Inc., 7 Tech Circle
Natick, MA 01760, USA
Phone +1 508 652 0900
Fax +1 508 652 0909
Email genelec.usa@genelec.com
In China please contact:
Beijing Genelec Audio Co, Ltd
Room 101, 1st Floor Building 71 B33
Universal Business Park
No.10 Jiuxianqiao Road,Chaoyang District,
Beijing 100015, China
Phone +86 (10) 5823 2014, Post code 100015
Email genelec.china@genelec.com
In Sweden please contact
Genelec Sverige
Ellipsvägen 10A
141 75 Kungens Kurva
Sweden
Phone +46 8 449 5220
Email info@genelec.com
SIGNAL PROCESSING SECTION
Signal connectors 7.1 channel analog IN/OUT
Analog Link IN/OUT
Digital AES/EBU IN/OUT
Analog signal input connector XLR female, balanced 10 kOhm
Maximum analog input signal
Analog input sensitivity (100 dB SPL at 1 m)
A
djustment range (LEVEL dip switches + rotary level control)
pin 1 gnd, pin 2 non-inverting, pin 3 inverting
+24.0 dBu
-6 dBu
+48 dBu to -6 dBu
Digital signal input connector XLR female 110 Ohm
Digital signal output / Thru connector XLR male 110 Ohm
Digital audio input
Word length
Sample rate
Digital input sensitivity (100 dB SPL at 1 m)
Digital input maximum attenuation
Positive input gain selection (GLM control)
AES/EBU Single Wire
AES/EBU Single Wire
16 - 24 bits
32 - 192 kHz
-30 dBFS
48 dB
+6, +12, +18 dB
Control network
Type
Connection
Proprietary GLM network
2 RJ45, CAT5 cables
GLM
TM
software frequency response adjustment parametric notch lters 20
System calibration Genelec GLM AutoCal™, GLM manual, Stand-alone
Crossover setting in subwoofer's input/output channels
Centralized Bass Management (for analog signal)
Distributed Bass Management (GLM control)
Input low pass xed 85 Hz, output high pass xed 85 Hz
Input low pass selectable 50 to 100 Hz, output no ltering
LFE cuto 120 Hz
Midband rejection >400 Hz ≥ 50 dB
Bass Roll-O control operating range in 4 dB steps 0 to -12 dB at 20 Hz
Phase matching control 90° steps with dip switch controls
15° steps with GLM control
AMPLIFIER SECTION
Short term amplier output power
(Long term output power is limited by driver unit protection circuitry)
800 W
Amplier system THD at nominal output <0.01%
Mains voltage 100-240 VAC 50/60 Hz
Power consumption
Standby, ISS active
Idle
Full output, peak
<2 W
40 W
600 W