Manual

7380A Operating Manual
Genelec Document D0148R001. Copyright Genelec Oy 5.2017. All data subject to change without prior notice
www.genelec.com
International enquiries:
Genelec, Olvitie 5
FIN-74100, Iisalmi, Finland
Phone +358 17 83881
Fax +358 17 812 267
Email genelec@genelec.com
In the U.S. please contact:
Genelec, Inc., 7 Tech Circle
Natick, MA 01760, USA
Phone +1 508 652 0900
Fax +1 508 652 0909
Email genelec.usa@genelec.com
In China please contact:
Beijing Genelec Audio Co, Ltd
Room 101, 1st Floor Building 71 B33
Universal Business Park
No.10 Jiuxianqiao Road,Chaoyang District,
Beijing 100015, China
Phone +86 (10) 5823 2014, Post code 100015
Email genelec.china@genelec.com
In Sweden please contact
Genelec Sverige
Ellipsvägen 10A
141 75 Kungens Kurva
Sweden
Phone +46 8 449 5220
Email info@genelec.com
SIGNAL PROCESSING SECTION
Signal connectors 7.1 channel analog IN/OUT
Analog Link IN/OUT
Digital AES/EBU IN/OUT
Analog signal input connector XLR female, balanced 10 kOhm
Maximum analog input signal
Analog input sensitivity (100 dB SPL at 1 m)
A
djustment range (LEVEL dip switches + rotary level control)
pin 1 gnd, pin 2 non-inverting, pin 3 inverting
+24.0 dBu
-6 dBu
+48 dBu to -6 dBu
Digital signal input connector XLR female 110 Ohm
Digital signal output / Thru connector XLR male 110 Ohm
Digital audio input
Word length
Sample rate
Digital input sensitivity (100 dB SPL at 1 m)
Digital input maximum attenuation
Positive input gain selection (GLM control)
AES/EBU Single Wire
AES/EBU Single Wire
16 - 24 bits
32 - 192 kHz
-30 dBFS
48 dB
+6, +12, +18 dB
Control network
Type
Connection
Proprietary GLM network
2 RJ45, CAT5 cables
GLM
TM
software frequency response adjustment parametric notch lters 20
System calibration Genelec GLM AutoCal™, GLM manual, Stand-alone
Crossover setting in subwoofer's input/output channels
Centralized Bass Management (for analog signal)
Distributed Bass Management (GLM control)
Input low pass xed 85 Hz, output high pass xed 85 Hz
Input low pass selectable 50 to 100 Hz, output no ltering
LFE cuto 120 Hz
Midband rejection >400 Hz ≥ 50 dB
Bass Roll-O control operating range in 4 dB steps 0 to -12 dB at 20 Hz
Phase matching control 90° steps with dip switch controls
15° steps with GLM control
AMPLIFIER SECTION
Short term amplier output power
(Long term output power is limited by driver unit protection circuitry)
800 W
Amplier system THD at nominal output <0.01%
Mains voltage 100-240 VAC 50/60 Hz
Power consumption
Standby, ISS active
Idle
Full output, peak
<2 W
40 W
600 W