User Manual
3
“DIGITAL IN AES/EBU” Connector
Use this female XLR connector for AES/EBU formatted digital
audio input signals. This input is selected automatically when
a valid digital audio signal is present, and overrides the analog
input.
Depending on the digital hardware, transmission of a 192 kHz
sample rate is achieved using a double speed, single chan-
nel/cable interface. This is called dual-wire mode. In this case
one cable per channel is used and no channel selection is
required. Dual-wire mode is automatically detected by the in-
put stage.
If the digital source device has a volume fader that controls
the digital level, it may be advantageous to lower the level
control either on the computer interface or on the monitor’s
back panel controls, which in turn will force the use of more of
the digital [bit] resolution in the volume control.
If the digital inputs are used, all audio outputs are referenced
to 0 dBFS (digital Full Scale, the largest level that may be rep-
resented in the AES/EBU signal). These monitors produce 100
dB SPL at 1 meter in free space for a digital input signal of
–30 dB FS.
“DIGITAL THRU AES/EBU” Connector
This male XLR carries an unaltered copy of the digital signal
fed into the “DIGITAL IN AES/EBU” connector. It can be used
for daisy-chaining up to four monitors together.
“ANALOG IN” Connector
Use this connector for analog audio signals. The maximum
input level is +7.0 dBu RMS on models 8240A and 8250A and
+22.0 dBu RMS on models 8351A and 8260A. When A/D con-
verter input clip occurs the front panel light turns momentarily
red, indicating the overload condition.
“CONTROL NETWORK” Connectors
Use these RJ-45 sockets to connect the monitor to the propri-
etary Genelec Loudspeaker Manager™ (GLM™) network only.
This connector is not Ethernet LAN compatible. Do not con-
nect to Ethernet LAN.
“12 V REMOTE” Connector (8260A only)
You can set up remote controlled powering up and down of
the 8260A with 12 V voltage connected to this connector. The
minimum current needed to actuate this function is 70 mA.
Front Panel Warning Light
Figure 2. Connectors and controls on the back panel of a 8260A. 8240A, 8250A and 8351A share the same layout but
without the 12 V trigger voltage connector.
dB
-2
-4
-8
-6
-12
0
-10
SWITCH
1
MANUAL
CTRL
-4 dB
160 Hz
ON +ON
OFF+OFF
-6 dB -6 dB -2 dB
STOREDDESKTOP
-2 dB -4 dB
BASS
ROLL-OFF
BASS
TILT
-2 dB -4 dB
+2 dB -4 dB
TREBLE
TILT
ON
OFF
SYSTEM LVL.AES/EBU CH.
AB
WF COAX
DRIVER MUTE
SWITCH
2
-10-20
dB
-30
SUMAANDB
MADE IN FINLAND
8260A DSP TRI-AMPLIFIED
MONITORING SYSTEM
MAGNETICALLY SHIELDED
SERIAL NUMBER
MAINS INPUT 230 V~
50/60Hz 330 W
DIGITALIN
AES/EBU
www.genelec.com
292-8260T-6
ANALOG
IN
DIGITAL THRU
AES/EBU
12 V
REMOTE
2
1
ON
OFF
ON
OFF
Stand-alone user
interface level control
Stand-alone user
interface switch
groups 1 and 2
GLM Control
Network
connectors
Mains power
switch
Mains input
connector
Analog input connector
Digital Thru connector
Digital input connector
12V Remote
connector
(8260A only)
Table 1. Monitor and subwoofer front panel light indications
summary
Device LED action Meaning and resolution
Steady green
Normal state
Slowly blinking green
Normal ISS power save state
From yellow to green
Normal operation during device start
Steady yellow
Monitor or subwoofer is not part of the group
Flashing red
Signal clip (analog)
Flashing red
Bit errors in incoming digital AES/EBU audio
Flashing red
Digital signal potential clip (digital audio is very
close to 0 dB FS)
Flashing yellow
Protection