Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 2 of 52 Table of Contents Introduction ..................................................................................................................................... 4 Glossary ......................................................................................................................................... 5 System Components....................................................................................................
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 3 of 52 Group Settings, Advanced Use ................................................................................................. 28 Access to group settings ........................................................................................................ 29 AES/EBU subframe A and B selections .................................................................................
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 4 of 52 Introduction Congratulations and thank you for purchasing Genelec Smart Active Monitoring (SAMTM) systems. Take a moment to familiarize yourself with the contents of this manual. While the use of the products is intuitive, there are many options and suggestions in this manual with regards to different types of installations and applications. For support contact your local dealer or support@genelec.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 5 of 52 Glossary Abbreviation or term Explanation 12xx Family of large three-way SAM monitors 72xx Family of digital audio input SAM subwoofers 73xx Family of analog and digital input SAM subwoofers 82xx Family of two-way and three-way SAM monitors 83xx Family of two-way and three-way SAM monitors with extended room compensation capability Adapter (8300-416) Genelec Network Adapter.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 6 of 52 System Components SAM Monitors Smart active monitors (SAM) are supported on Genelec’s GLM control network. Genelec has a very large selection of SAM monitors, ranging from compact two-ways to large three-way main monitors. SAM Subwoofers Smart active subwoofers are supported Genelec’s GLM control network.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 7 of 52 Getting Started To take full advantage of your Smart Active Monitoring (SAM) system it is important to become familiar with all the components in the system. To set up a monitoring system you will need monitors and subwoofers, audio signal cables, GLM control network cables, GLM network adapter, GLM measurement microphone, and GLM 2.0 software.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 8 of 52 Cabling for Audio Signals Run all audio cables from the audio source to the monitors. When a subwoofer is used, run the same signal to the monitor and the subwoofer. We recommend running the signal to the subwoofer first. The subwoofer has output connectors to facilitate onward connection to the monitor.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 9 of 52 Figure 3. Analog stereo cabling with a subwoofer Analog 5.1 Surround Example Before cabling, turn off the power in all monitors and subwoofers.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 10 of 52 Digital Audio, Stereo with a Subwoofer Example Before cabling, turn off the power in all monitors and subwoofers. An example of the audio cabling for AES/EBU digital audio is shown in Figure 5.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 11 of 52 from the surround right monitor DIGITAL OUT to surround left monitor DIGITAL IN Center/LFE channel pair from the AES/EBU output of the audio source to the subwoofer DIGITAL INPUT4 connector from the subwoofer DIGITAL OUTPUT4 to the center monitor DIGITAL IN Figure 6.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 12 of 52 reproduced have to be selected on each monitor. The figure below also shows the dip switches position for the required A or B channel selection.
Genelec Loudspeaker Manager (GLM) 2.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 14 of 52 Figure 8. An example of an AES/EBU digital audio surround cabling with SE7261 and digital channel selections for each monitor. Cabling of the Control Network The GLM control network cabling is very easy. Connect the computer USB port to the GLM adapter. Connect the GLM adapter to all SAM monitors and subwoofers in daisy-chain fashion (Figure 9) using the GLM network cables supplied with each monitor and subwoofer.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 15 of 52 Connector Use USB (type B) Connects the GLM adapter to a computer USB interface or USB power supply (stand-alone volume control) Volume (3.5 mm jack) Connection for Genelec volume controller Microphone (3.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 16 of 52 Downloading and Installing GLM Software The GLM software calibrates and controls Genelec SAM systems. The software can be downloaded at www.genelec.com/glm. You must have sufficient rights to install the software in your computer. Install the software following the instruction given by the software during the installation process. We recommend you install the software on the local hard drive.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 17 of 52 Figure 11. Drag and drop the monitor icons onto the layout grid to build a system layout Use your mouse to drag and drop monitors or subwoofers onto the layout. Drag a monitor or subwoofer icon from the stack to the layout grid on the right and drop it to the position that matches its position in the room. Continue this until the stack is empty.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 18 of 52 Figure 13. The steps of creating a SAM system layout The additional display box ‘Not used in this setup’ is primarily used with Small Environment (SE) systems (SE7261). It defines the number of unused 8130s with the SE7261 subwoofer. For example, the SE7261 can support up to 8 x 8130s and the system setup starts with 8 SE channels on the Stack. They are labeled 1A, 1B all the way through 4B.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 19 of 52 Figure 14. Location of the 'Not used in this setup' bin. Creating a SAM Monitor Group A SAM monitoring group is a set of monitors and subwoofers that reproduce audio together. A group contains settings that can optimize every monitors and subwoofers. To define a monitoring group: give the group a name (1) that describes it (e.g.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 20 of 52 Figure 15. Group definition window; the monitors with a green halo is active; monitors with a yellow halo are not part of the active group Automatic Calibration Using GLM AutoCal GLM AutoCal is a powerful monitoring system calibration algorithm running inside the GLM software. Sweeps are generated by each monitor in a group. Responses are recorded with the GLM measurement microphone into your computer.
Genelec Loudspeaker Manager (GLM) 2.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 22 of 52 Aligning Subwoofer Phase with GLM AutoPhase The purpose of the GLM AutoPhase is to set the subwoofer phase at the crossover frequency in relation to a selected monitor so that the combined response of the subwoofer-monitor system is flat across the crossover region. Figure 17.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual click ‘Confirm Calibration’ to save the settings For more detailed information, see the section on Advanced use of AutoPhase.
Genelec Loudspeaker Manager (GLM) 2.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 25 of 52 Group Tabs A group is activated by clicking on the group tab.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 26 of 52 Advanced Use of GLM GLM is the most powerful tool available to calibrate and control a Genelec SAM monitoring system. The following chapters introduce advanced use of the GLM. Maximum Number of Groups Each system setup file can contain up to five (5) groups. You can create new groups with the ‘Group | Add Group’ menu command or the ‘Group | Duplicate Group’ menu command.
Genelec Loudspeaker Manager (GLM) 2.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 28 of 52 Access to Monitor and Subwoofer Settings Access to monitor and subwoofer acoustical calibration and settings is available by double-clicking on the monitor and subwoofer icons from the GLM Main page. You can also use the ‘Group’ system menu items to access monitor and subwoofer acoustical settings.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 29 of 52 Figure 19. An example of a GLM system setup having three monitoring groups Each group contains group-specific settings. These settings can optimize the performance of SAM monitors and subwoofers for different situations and purposes.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 30 of 52 Figure 20. Common settings for a SAM group are presented on the left side of the SAM group definition display. Table 2. Group level settings Setting Description Group Name A Group has a name. The name may tell what kind of SAM Group is playing (e.g. ‘stereo’) or describe the listening location (e.g. ‘mixing position’ or ‘producer’). Input Signal Type A group is configured for analog or AES/EBU digital audio.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 31 of 52 Group Signal Type A group is configured for analog or AES/EBU digital audio. Certain products only have analog or AES/EBU digital inputs. You cannot include products in a group reproducing selected audio type (analog or digital), if these specific products do not have the correct input type available.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 32 of 52 Group setting specific to a single monitor (83xx Series) This section explains the group-specific controls available for monitors. Table 3. Group settings for monitors (83xx Series) Setting Description Monitor Name Name that helps you identify this monitor In Group When the setting is ON this monitor belongs to the current group. When the setting is OFF this monitor is not in the group and will not play audio.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 33 of 52 Group setting specific to a single subwoofer (73xx Series) This section explains the group-specific controls available for SAM subwoofers having analog and digital audio inputs. Table 4. Group settings for subwoofer (73xx Series) Setting Description View Subwoofer Name Name tag to help identify this subwoofer Using analog input In Group When this setting is ON this subwoofer belongs to the current group.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 34 of 52 Group setting specific in subwoofers having only digital inputs (72xx Series) This section explains the group-specific controls available for SAM subwoofers having only digital audio inputs. These subwoofer are fully compatible with GLM 2.0 but naturally cannot accept any analog input directly. You can use these subwoofers with analog signals using a separate analogto-digital converter. Table 5.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 35 of 52 Table 6. Group settings for legacy subwoofer, with digital audio input (72xx Series) Setting Description Subwoofer Name Name tag to help identify subwoofer In Group When this setting is ON the subwoofer belongs to View the current group. When the setting is OFF the subwoofer is not in the group and does not play audio. AES/EBU Digital Channel These controls select the subframes that the subwoofer reproduces.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 36 of 52 Table 7. Group settings for SE Monitor (8130) with analog input (available with SE7261) Setting Description Monitor Name Name tag to help identify monitor (note) 8130 monitors controlled with SE7261 and GLM cannot be used with analog signals as SE7261 supports only AES/EBU digital audio. View Table 8.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 37 of 52 Table 9. Group settings for SE7261 with analog input Setting Description Subwoofer Name Name tag to help identify subwoofer (note) SE7261 cannot be used with analog signals as SE7261 supports only AES/EBU digital audio.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 38 of 52 Table 10. Group settings for SE7261 with digital audio input Setting Description Subwoofer Name Name tag to help identify subwoofer In Group When this setting is ON the subwoofer belongs to the current group. When the setting is OFF the monitor is not in the group and does not play audio. AES/EBU Digital Channel These controls select the subframes that the subwoofer reproduces.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 39 of 52 Using Bass Management Filter Settings The Bass Management Filter (subwoofer crossover frequency) is normally set in the subwoofer group settings. When the Bass Management setting is marked ‘global’, the Bass Management Filter setting is applied to all monitors in the group.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual reposition the measurement microphone to the primary listening position review the result by clicking on the monitor and subwoofer icons continue to AutoPhase when there is a subwoofer in the system accept the calibration result with the ‘Confirm Calibration’ button page 40 of 52 Figure 22.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 41 of 52 Figure 23. Reviewing the corrections by clicking on the monitor and subwoofer icons Advanced use of AutoPhase AutoPhase uses the selected Bass Management Filter frequency setting together with the selected monitor. The purpose of AutoPhase is to align the subwoofer phase with the reference monitor so that the frequency response across the bass management crossover is flat.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 42 of 52 Editing Acoustic Calibrations Acoustic Editors Acoustic settings editor opens with several methods double-click on a monitor or subwoofer icon in the main window right-click on the icon and select ‘Edit Acoustics’ menu select the ‘Groups | Edit Acoustics All’ menu command (opens settings of all monitors and subwoofers) Measured frequency responses are shown in the editor if the group has been calibrated.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 43 of 52 Descriptions of the Acoustical Settings Table 11. Acoustical settings Setting Description Frequency response graphs Measured frequency response (red), room calibration filter (blue), compensated room View frequency response (green). Monitor Info Information about the monitor Test Controls Controls to turn on and off the drivers and the test signal generators Level and delay Sensitivity adjustment (level).
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 44 of 52 Figure 25. Level and time-of-flight correction controls Room Response Equalizer Controls Each SAM monitor and subwoofer contains a set of tools to compensate for the acoustical influences of the room. These tools include high frequency shelving filters (filters 1 and 2), low frequency shelving filters (filters 3 and 4), and parametric notch filters (filters 5 to 20).
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 45 of 52 Stand-Alone Operation SAM monitors and subwoofers are set up and calibrated using GLM control network and GLM 2.0 user interface software. After setup, monitors, subwoofers and the GLM adapter can also operate without having a computer connected to the GLM adapter. This is called stand-alone operation.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 46 of 52 Connecting the GLM Volume Controller The volume controller is connected to the GLM adapter via 3.5 mm jack showing a level control triangular sign. See the bottom of the GLM adapter for more information. Caution: Be sure to turn the volume controller fully counter-clockwise (level down) before connecting the volume controller to the GLM Network Adapter. Figure 28.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 47 of 52 adapter. The typical operating range is 30 meters. The wireless controller works with the GLM adapter after pairing. The pairing happens during the first 10 seconds after powering up the adapter. The wireless controller can increase and decrease the sound level and turn the system on and off. For more information on the wireless volume controller, consult your Genelec sales representative. Figure 29.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 48 of 52 Display indications summary GLM display indications summary Table 12.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 49 of 52 Monitor and subwoofer LED light indications summary Table 13.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 50 of 52 Frequently Asked Questions Why do ID tones vary in different system configurations? Different SAM monitors generate different identification tones. The identification tones are listed in the table below. Table 14.
Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual page 51 of 52 Can analog and digital signal sources be mixed? Yes and no. One type of signal can be used in one group. However, it is easy to create two groups, one for analog input and another for digital audio input. After this, switching from one group to the other will select the input signal type. How to switch between analog and digital signal? Groups can be defined to select analog or digital input signal.
International enquiries In Sweden In the U.S.A. In China Genelec, Olvitie 5 FI 74100, Iisalmi, Finland T +358 17 83881 F +358 17 812 267 E genelec@genelec.com Genelec Sverige Ellipsvägen 10B P.O. Box 5521, S-141 05 Huddinge Sweden T +46 8 449 5220 F +46 8 708 7071 E info@genelec.com Genelec, Inc., 7 Tech Circle Natick, MA 01760, U.S.A. T +1 508 652 0900 F +1 508 652 0909 E genelec.usa@genelec.com Beijing Genelec Audio Co.Ltd Room 101, 1st floor, Building 71 B33, Universal Business Park No.