Digital I/O
Digital inputs are automatically mapped to certain places
and used within the program. Further custom mapping
such as an input to an output can be performed by the
user as desired. Mapping is performed by channel
numbers.
Digital Outputs and Digital Output Functions follow a
similar concept with Channels and Function names. The
term Digital Output refers to a physical output, and
setting up a Digital Output maps a Source to operate that
physical output. A Source can be a Digital Input called a
Physical Source, an internal control output (such as
“Crank”) called a Control Source, or a Digital Output
Function. There are 48 possible channels an output can
be mapped to, but there are only 21 physical outputs on
the Main Controller. This is to allow for future expansion.
The term Digital Output Function (DOF) refers to a list of
possible program outputs which are not necessarily
needed for program operation, but could be useful to a
user. Up to 208 DOFs can be configured for use.
Digital Input (DI) Setup
1. See Figure 3-58. Select the digital input channel to
modify by clicking on its name in the Digital Input
Diagnostics screen.
2. Select the physical input source (A).
3. Select the function code (B).
4. Check the “Invert” box (C) to change the digital
polarity if desired. “Invert” means a grounded input
pin will show as “HIGH”.
5. Click “Apply Changes” (D).
Figure 3-58. DI Setup
Digital Output Function (DOF) Setup
To configure a digital output function channel:
1. Select an unused channel number by pressing the
"Show Null Functions" button.
2. If selecting a User Config DOF, an Alternate Name
must also be provided.
3. Select “Apply Changes”.
Digital Output Channels (DO) Setup
1. See Figure 3-59. Select an unused channel ID by
selecting the digital output channel name in the
Digital Output Diagnostics screen.
Figure 3-59. DO Diagnostics
2. Select the channel ID. The channel ID is the same
as the output.
3. See Figure 3-60. Select the type of source (a pick
list will be displayed) (A). Physical Source is for
mapping a Digital Input Function to the Output.
Control Source is for mapping an internal control
signal to the Output. DOF is for mapping a Digital
Output Function to the Output.
4. Select the required function code (B).
5. Check the “Enable” box (C) to enable the output.
6. Check the “Invert” box (D) to invert the digital
polarity, if desired. “Invert” means the pin is
grounded when the output shows as “HIGH”.
7. Click “Apply Changes” (E).
Figure 3-60. DO Setup
007563
A
B
C
D
010388
007566
A
B
C
D