Technical Diagram
- 1 PWRcell Inverter    - 1 CT Kit (included)
- 3 PV Links (max 6) 
- 1 PWRcell Battery
This design shows a PWRcell system with a Protected 
Loads panel to provide backup power to loads. This design 
uses a line-side tap to connect the inverter input when 
backfeeding via the main panel is not feasible or in 
compliance.
This configuration is acceptable for use with most utility 
services. 
30A
30A
30A
30A
Power Conversion
PWRcell
TM
 Inverter 
Generac 
PowerCore
Router
Ethernet (CAT5)
50A
AC Grid
Main Distribution
Panel
M
Protected Loads Panel
AC 
Combiner Panel
Line-Side Tap
(Supply-Side Connection)
CT (CAT5)
40A
Storage
PWRcell Battery 
PV Array
PV Optimization
PV Link
TM
Substring Optimizer
REbus
TM
 DC nanogrid
Powered by REbus (DC Voltage)
AC Voltage
FOR REFERENCE ONLY; NOT FOR CONSTRUCTION. 
*Installer responsible for code compliance.
*Refer to product manuals for additional installation 
details and requirements.
Line-Side Tap / Solar + Storage 
Reference Code-
13
13-01
Page 5 of 11
Part No. A0000521683 Rev. D 03/10/2020
© Generac Power Systems, Inc. All rights reserved
Generac Power Systems, Inc.
S45 W29290 Hwy. 59
Waukesha, WI 53189