Manual

TROUBLESHOOTINGGUIDE
Enginewon't start.
1. No fuel in tank.
2. Fuelvalve turned off.
3. Defectivespark plug.
4. Pluggedfuelfilter.
5. Defectiveor stuck enginestop switch.
1. Add fuel to tank.
2. Turnfuel valve on.
3. Replacespark plug.
4. Replacefuel filter.
5. Replaceenginestart switch.
Enginestarts, then shuts down.
1. Low fuel level.
2. Fueltank ventclosed.
3. Incorrect engineoil level.
4. Contaminatedfuel.
5. Defectivelow oil level switch.
6. Defectiveignition coil.
1. Add fuel to tank.
2. Openfuel tank vent.
3. Checkengineoil level, add or drain as needed.
4. Replacefuel filter.
5. ReplaceLow Oil Levelswitch.
6. Replaceignition coil.
Enginestarts, then runs rough.
1. Chokeis stuck or left on.
2. Dirty or clogged airfilter.
3. Defectiveor dirty spark plug.
4. Dirty fuel filter.
5. DefectiveFlexPowerswitch.
1. Turn choke off.
2. Cleanor replacethe airfilter element.
3. Replacespark plug.
4. Replacefuel filter.
5. ReplaceFlexPowerswitch.
No AC output. 1. Generatoris overloaded(OVERLOADLEDis on).
2. ACvoltage is low (OVERLOADLED is on).
3. Inverter moduleis overheated(OVERLOADLEDis
on).
4. Short circuit in load (OVERLOADLED is on).
5. Defectiveinverterassembly.
1. Shut down generatorto reset module. Reduce
loads andrestart generator.
2. Verify vent is open and choke is OFF.
3. Verify service door is ON.Let cool for 15 minutes
and restart generator.
4. Verify condition of any extensioncords and all
loads being powere.
5. Replaceinverter assembly.
' ! !
No DC output. ** 1. DC circuit breakeris open. 1. ResetDC circuit breaker.
2. DefectiveDC circuit breaker. 2. ReplaceDCcircuit breaker.
3. Defectiverectifier. 3. Replacerectifier.
Fuelleaks from drain hoses. 1. Fuelsystem over primed (flooded). 1. Turn vent in cap ONand let generatorsit 15
minutesbefore restarting.
2. Carburetordrain in bowl is not closed. 2. Turn valve clockwise to close.
* Engine speed increases and decreases -- This is normal as the generator starts u and as loads vary.
** Verify FlexPowerSwitch is inthe "O" OFFposition.