Owner's Manual
H. Turn OFF and unphg ALL eHectricaHHoadsfrom
generator paneHreceptacles. NEVER start or stop engine
with eHectricaHdevices plugged in and turned ON.
2. Move idHe control switch to"Off' position.
3. Let engine run at noqoad for severaH minutes to
stabilize internaH temperatures of engine and generator.
4. Turn engine off according to instructions given in the
engineowner's manual.
S. Move fuelvalveto"Off' position.
Operating Automatic Idle Control
This switch is designed to greatly improve fuel economy.
When this switch is turned ON_ the engine will only
run at its normal high governed engine speed when
electrical loads are connected.VVhen an electrical load is
remove& the engine will run at a reduced speed.
With the switch off, the engine will run at the normal
high engine speed. Always have the switch off when
startingand stopping the engine,
Charging a Battery
Your generator has the capability of recharging a
discharged 12VoN automotive or utility style storage
battery. DO NOT use the unit to charge any 6VoN
batteries. DO NOT use the unit to crank an engine having
discharged battery.
DANGER
DO NOT ailow any open flame, spark,heat, or lit cigarette
during and for several minutes after charging a battery.
Wear protective goggJes, rubber apron, and rubber gloves.
w
To recharge m2 Vomt batteries, proceed as follows:
I. Check fluid level in all battery cells. If necessary, add
ONLY distilled water to cover separators in battery
cells. DO NOT use tap waters
2. If battery is equipped with vent caps, make sure they
are installed and are tight.
3. If necessary, clean battery terminals.
4. Connect battery charge cable connector plug to panel
receptacle identified by the words "12oVOLTS D.C.".
5. Connect battery charge cable clamp with red handle
to the positive (+) battery terminal (Figure 7).
12VOLT DoCo
POS NEG
6. Connect battery charge cable clamp with bmack handle
to the negative (-) battery terminal (Figure 7).
7. Start engine. Let engine run while battery recharges.
8. When battery has charged, shut down engine.
NOTE: Use an automotive hydrometer to test battery state
of charge and condition. Follow the hydrometer
manufacturer's instructions carefully. Generally, a battery is
considered to be at 100% state of charge when specific gravity
of its fluid (as measured by hydrometer) is 1.260 or higher.
COLD WEATHER
OPERATION
Under certain weather conditions (temperatures below
40°F [4°C] combined with high humidity), your generator
may experience icing of the carburetor and/or the
crankcase breather system.To reduce this problem_ you
need to perform the following:
I. Make sure generator has dean_ fresh fuel.
2. Open fuel valve (turn valve to open position).
3. Use SAE SWo30 oil (synthetic preferred, see engine
manual).
4. Check oil level daily or after every eight (8) hours of
operation.